Soleus Air air-condition Air Conditioner User Manual


 
No heat 1. Power is off.
2. Set temperature is in
improper position
3. Connector has fallen off.
4. Heater is defective
5. Fuse is open.
6. Control panel is not
working.
Check the circuit
Adjust the set value
Tighten the plug.
Change the heater.
Change the fuse.
Change the circuit panel.
The fan doesn’t operate 1. Control panel is faulty.
2. The capacitor of fan
defective.
3. Fan defective.
Change the panel.
Change the capacitor.
Change the fan.
Unusual sound or heavy
shaking
1. Installation of the
air-conditioner too
gradient.
2. Fan touches with other
hardware.
3. The connective pipelines
collide with each other.
4. The part becomes flexible.
Check Installation.
Adjust the fan position.
Adjust the position between
the pipelines.
Tighten screws.
Installation
1. Installation preparation
If you need to install the air-conditioner on already existing roof vent, the measure of vent
must reach 14×14 (in). If it is not enough of this measurement, you must extend this
measurement. If it is larger than this measurement, you must make a wood frame for the vent
to meet above measurement.
The gradient of install the platform must no more than 5°. If greater than 5° it can be
influenced that condensation water of the air conditioner could overflow.
You must avoid any wire and any pipeline before incision.
2. Please directly install the top of the air-conditioner on the placket and make windward face
toward the front of the vehicle, condenser toward the back of the vehicle. Put the seal
between air-conditioner and placket, and you can sight the four M10 install bores in the
air-conditioner bottom. To those irregular coarse roofs you must have sealant seal up all gaps
in order to prevent rainwater infiltrating into room.
7