SkyLink HA-434T Home Security System User Manual


 
The Indoor/Outdoor Motion Sensor is designed to monitor movement
around your house. The motion sensor can be placed either indoor or
outdoor. Once motion is detected, the receiver will beep & flash.
In this package, you should find an Indoor/Outdoor Motion Sensor, ball-
head joint, screws and a clip.
Please follow the instructions below to setup your motion sensor.
2 pcs 3 x 18 screws
(Included)
Indoor/Outdoor
Motion Sensor
Ball-head joint
Clip
Indoor/Outdoor
Motion Sensor
1. INTRODUCTION
Model HA-434T
3. POWER UP THE INDOOR/OUTDOOR MOTION SENSOR
In order for the sensor to communicate with the receiver properly, the
sensor’s code must match with the receiver’s code. Code connectors 1
to 6 can be found by opening the battery cover and back cover of the
receiver. User is required to set these code connectors randomly and
the code settings on both sensor and receiver must be the same. Each
position of the code connector can be set to “+”, “-‘ or “0” positions.
Refer to the diagram below to set the code connectors properly. If the
connector is placed on the top and middle posts, that column is set on “
+ ”. If the connector is placed on the middle and bottom posts, that
column is set on “ - ”. If the connector
is removed completely, (not placed on
any posts), it is set to “ 0 ”. (see diagram
for examples of how to set a column
to the three different positions).
Code Connectors on Motion Sensor
1. CODE CONNECTORS
Note: If you experience interference from a nearby system, which could
accidentally trigger your system, please change the code settings on
the sensor and receiver. The code setting on the sensor and receiver
should still match after changing the code setting.
‘+’
‘-’
0
2. SET UP THE INDOOR/OUTDOOR MOTION SENSOR
Clip
Note: A connector can be removed with
the clip, as shown.
Each receiver can work with up to 4 different sensors (to represent 4
different zones on the receiver). There are 2 connectors that determine
the zone number 1, 2, 3 and 4. These 2 connectors can be found by
opening the battery cover. Please follow table 1 to set the zone.
Zone connectors
2. ZONE CONNECTORS
“+” in the table means the connec tor for that position should be placed on
the posts.
“-“ in the table means the connector for that position should be removed.
A B
Zone 1 + +
Zone 2 + -
Zone 3 - +
Zone 4 - -
Table 1
1. POWER UP
Insert 9V alkaline battery to the sensor
After mounting the sensor at the desired location,
it is important to perform a walk test in order to
determine if the sensor is detecting the things you
want to detect.
In order to control how far the sensor can “see”, this can be done by
adjusting the angle of the sensor. To reduce the detection range, simply
move the sensor downward. To increase the range, move the sensor
up to around 12 degrees. This will give the maximum range. However,
this may not be desired if the sensor is placed outdoors, since a false
trigger may occur if the sensor is set to detect motion in a distance.
You should walk in the area that you would like the sensor to monitor.
The receiver will beep if the sensor detects your movement. If the
receiver does not respond, adjust the mounting angle accordingly.
Perform the walk test again after 30 seconds. Repeat this procedure
until your motion is detected. There should be no movement in the
detected area during the 30 seconds.
Perform walk test in the undesired area to ensure movement cannot be
detected.
4. WALK TEST
The sensitivity of the motion sensor is adjustable. Change the setting by
placing the connector on either the ”High” or “Low” position. When the
sensitivity is set to “Low”, more movement is required to trigger the
sensor. It is recommended to set the sensitivity to “Low” and perform a
“Walk Test” (Described in Section 3 -
“Walk Test”). If the walk test result is
satisfied, the sensitivity does not
require to be adjusted further. If the
walk test result shows the sensitivity
is too low, then you can change the
sensitivity setting to “High”. Please
perform the walk test after changing
the sensitivity setting.
2. SENSOR SENSITIVITY
Sensitivity Connectors
on Motion Sensor
A ball-head joint is necessary to mount the sensor at a desire location. A
height of 5-6 ft is recommended, depending on your application. Once a
location is selected, mount the ball-head joint to this location by screws
provided, (see diagram 1). Once the ball-head joint is mounted to the wall,
slide the back of the sensor into the ball-head joint (see diagram 2). The
mounting angle can be adjusted. Please refer to Section 3 “Walk Test” to
determine the best mounting angle.
3. MOUNTING
Diagram 1
Diagram 2
Insert a 9V alkaline battery (not
included) to the motion sensor and its
LED will be on for 2 seconds. The
receiver will beep and red LED flash.
The sensor requires a warm up time
of approx. 45 seconds before it can
function properly. After powering up
the sensor, face it to the wall where
no motion will be detected. After 45
seconds, the sensor is ready. Wave
your hand in front of the sensor, the
receiver will beep and red LED will
flash for approx. 15 seconds.
After setting up all the connectors properly, the sensor is now ready to be
powered up.