SkyLink HA-400 Home Security System User Manual


 
The sensor must be programmed to the Household Alert
®
Long Range
Receiver before they can communication. You may program the sensors
to one of the 4 zones. Follow the instructions below:
1. Plug in an AC adapter to the receiver.
2. The green LED will be on indicating it is turned on.
3. Open the back cover and there is a learn button. Press and hold this
learn button for 5 seconds, until both green LED and
zone 1 red LED
You may now release the learn button.
4. If you would like to program the sensor to zone 1, activate the
sensor while the zone 1 red LED is
Press the SET button
on the back of the sensor to activate it.
5. If you would like to program the sensor to other zones, press the
learn button again, until the red LED
at the zone you want to
program the sensor to, then activate the sensor.
6. Once the sensor is programmed, the green LED will be steadily on
and none of the red zone LEDs will be on.
Note: Each zone can program up to 4 sensors. If you try to program a
sensor into a zone, the programmed sensor will be erased.
Erasing a sensor
You cannot erase a
sensor. You must erase all sensors from
the receiver, then program the ones you would like to keep. To erase
all the sensors from the receiver:
1. Remove the adapter from the receiver.
2. Open the back cover, press and hold the learn button. Do not
release the learn button until step 4.
3. While holding onto the learn button, plug in the adapter to the receiver.
4. You may release the learn button whe
n the LEDs on the receiver are on.
5. You have erased all sensors from the receiver.
1. INTRODUCTION
Deluxe Home Monitoring Kit
Model
HA-400
In this package, you should nd two Window/Door Sensors, a Motion Sensor,
a Household Alert Long Range Receiver, an adapter, ball-head joint, screws
and other mounting accessories.
Please follow the instructions below to setup your motion sensor and
the receiver.
Adapter
2 pcs 3 x 18 screws
(Included)
Indoor/Outdoor
Motion Sensor
Ball-head joint
Plug in the adapter to the receiver
Insert 9V alkaline battery (option) to the sensor
2. PROGRAMMING MOTION SENSOR
3. MOTION SENSOR INSTALLATION
A ball-head joint is necessary to mount the sensor at a desire location.
A height of 7 ft is recommended, depending on your application. Once a
location is selected, mount the ball-head joint to this location by screws
provided. Once the ball-head joint is mounted to the wall, slide the back
of the sensor into the ball-head joint. The mounting angle can be
adjusted. Please refer to “Walk Test” to determine the best mounting
angle.
After mounting the sensor at the desired location, it is
important to perform a walk test in order to determine
if the sensor is detecting the things you want to detect.
In order to control how far the sensor can “see”, this can be done by
adjusting the angle of the sensor. To reduce the detection range, simply
move the sensor downward. To increase the range, move the sensor
up to around 12 degrees. This will give the maximum range. However,
this may not be desired if the sensor is placed outdoors, since a false
trigger may occur if the sensor is set to detect motion in a distance.
You should walk in the area that you would like the sensor to monitor.
Place the slide switch on the side of the receiver to “Alert” position. The
receiver will beep if the sensor detects your movement. If the receiver
does not respond, adjust the mounting angle accordingly. After motion is
detected once, the sensor will not be triggered unless no motion is
detected for 20 seconds. Therefore, wait for at least 20 seconds during
walk testing between 2 activations.
Perform walk test in the undesired area to ensure movement cannot be
detected.
Household Alert
®
Long Range Receiver
SET Button
7 ft
Tips: The sensor should not face towards direct sunlight, placing near
heat or cold producing devices (i.e. A/C or furnance vents, fans, ovens,
heaters etc.) that may cause false triggers.
Move the sensor downward to
reduce the range.
Move the sensor up to around
12 º to give maximum range.
The sensitivity of the motion sensor is adjustable. Change the setting by
placing the connector on either the ”High” (connector position “1”) or
“Low” (connector position “2”) position. When the sensitivity is set to
“Low”, more movement is required to trigger the sensor. It is recom-
mended to set the sensitivity to “Low” and perform a “Walk Test”. If the
walk test result is the sensitivity does not require to be
adjusted further. If the walk test
result shows the sensitivity is too
low, then you can change the
sensitivity setting to “High”. Please
perform the walk test after changing
the sensitivity setting.
1 - High 2 - Low
Learn Button
Mounting
Accessories
2 x Magnet Sensor
The Deluxe Home Monitoring Kit is designed to monitor movement or any
door and window around your house. The motion sensor can be placed either
indoor or outdoor. Once motion is detected or a window/door is opened, the
receiver will ash along with alert beeping or alarm.
®
SENSOR SENSITIVITY
WALK TEST
MOUNTING
Page 1 of 3