ENFORCER FLUSH-MOUNT OUTDOOR ACCESS KEYPAD
QUICK REFERENCE GUIDE
1. Using the User Codes:
A. User codes operate the door (4-8 digits long).
Press u u u u
B. The # key must be pressed also if the keypad is in manual-entry mode.
Press u u u u #
2. Using the Master Code:
The Master Code can be used to operate the door or program the keypad (4-8 digits long, see section 5 below).
Press x x x x # 1 (Output #1)
Press x x x x # 2 (Output #2)
3. Using the Inhibit/Lockout Code
Please contact your installer for an explanation of inhibit mode and its operation.
4. Using Duress Codes
For a full explanation of duress codes and their uses, see pg. 12.
5. Delete/Add/Change User and Master Code
WARNING – Press the correct option key. If the option key is not used and a “0” is pressed after entering the
Master Code, it could accidentally reprogram the Master Code.
A. Enter the Master Code first, followed by the key.
(If you forgot the master code, see page 15 for more information.)
Press x x x x
B. Changing/Adding Users:
Press 1 00-99 (user ID) u u u u (user code, 4-8 digits) # (for output #1)
Press 2 0-9 (user ID) u u u u (user code, 4-8 digits) # (for output #2)
C. Deleting Individual Users:
Press 1 00-99 (user ID) # (for output #1)
Press 2 0-9 (user ID) # (for output #2)
D. Changing the Master Code:
Press 0 x x x x # (Where x x x x is the new master code.)
E. To exit programming mode, press the key.
LIFETIME LIMITED WARRANTY This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for the
lifetime of the product. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to
SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or
abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than
defects in material and workmanship. The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to repair or replacement only, at
SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damages of any kind to the
purchaser or anyone else. This lifetime limited warranty is for products sold and installed in the United States and Canada. For all other countries, the warranty is 1
(one) year.
NOTICE The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy is one of continual
development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for
misprints or typographical errors. Copyright © 2009 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part,
without the written permission of SECO-LARM.
U.S.A., Inc.
16482 Millikan Avenue, Irvine, CA 92606 Website: www.seco-larm.com
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326 E-mail: sales@seco-larm.com
PIHAK1
mi-SK-1123-FQ.docx
Note: u u u u
indicates user code.
Note: x x x x
indicates master code.
MANUAL
SK-1123-FQ
Flush-Mount Outdoor Access Keypad
Page 16
Also available from SECO-LARM:
SK-1011-SQ
SK-1131-SQ
Indoor Keypads
Outdoor Keypads
SK-2123-SQ
SK-3123-SQ
SK-1123-SQ