SECO-LARM USA E-942SA-600 Door User Manual


 
ELECTROMAGNETIC LOCK Installation ManualELECTROMAGNETIC LOCK Installation Manual
SECO-LARM U.S.A., Inc.
When power is applied to the electromagnetic lock, it turns on the unit's
powerful built-in electromagnet. This electromagnet is attracted to the steel
armature plate which is mounted on a door, holding the door fast against
unauthorized entry. When power to the magnetic lock is turned off, the
electromagnet releases the armature plate, allowing the door to open.
SPECIFICATIONS
80-LB. MINIATURE
ELECTROMAGNETIC LOCKS
12~24VDC
2
3
/
4
x 1
1
/
4
x
13
/
16
in. (70 x 31 x 20 mm)
2
3
/
8
x 1
1
/
4
x
23
/
64
in. (60 x 31 x 9 mm)
80 lb. (36kg.) @ 12VDC
110lb.(51Kg.) @ 24VDC
85mA @ 12VDC
165mA @ 24VDC
± 10%
Aluminum
14°F to 131°F (-10°C to 55°C)
0.90 lb. (410 grams)
HOW THEY WORK
Installation Manual
E-941SA-80Q
Also available:
E-941SA-1200
1200-lb. electromagnetic lock
E-941SA-600
600-lb. electromagnetic lock
E-941SA-300
300-lb. electromagnetic lock
E-941SA-1K2PD
1200-lb. electromagnetic lock with status LED status sensor & delay timer
E-941DA-1K2P
Double-Door 1200-lb. electromagnetic lock with status LEDs & status sensors
E-942SA-1300
1300-lb. water-resistant gate lock
E-942SA-600
600-lb. water-resistant gate lock
Page 4
Power
Magnet Size
Armature Size
Holding Force
Current Drain
Voltage Tolerance
Housing
Temperature
Weight
PITLW1
Filename: MIE941SA-80_056.PMD
REGULAR MAINTENANCE
Clean the contact surfaces of the electromagnet or armature plate with a soft cloth and non-
abrasive, non-corrosive cleaner.
Apply a light coat of a silicon lubricant and wipe away the excess to prevent rust.
Check that the armature plate is securely attached to the door, yet can pivot slightly around the
armature screw.
Check that the electromagnet is securely attached to the door frame.
TROUBLESHOOTING
Problem:
Door does not lock
Door locks, but can be easily
forced open
Delay in door releasing
Possible cause:
No power
Poor contact between
electromagnet and
armature plate
Insufficient voltage
A secondary diode was
installed across the
electromagnet
Solutions:
Check to make sure the wires are connected
properly.
Check that the power supply is connected and
operating
Make sure the lock switch is wired correctly
Make sure the electromagnet and armature plate
are properly aligned
Make sure the contact surfaces of the
electromagnet and armature plate are clean and
free from rust
Check the power leads with a meter, and make
sure power is supplied between 12~24VDC.
The electromagnet is fitted with a metal oxide
varistor to prevent interference, so do not install a
secondary diode
NOTICE
The information and specifications printed in this manual are current at the time of publication.
However, the SECO-LARM policy is one of continual development and improvement. For this
reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is
also not responsible for misprints or typographical errors.
Copyright © 2005 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be
reproduced or copied, in whole or in part, without the written permission of SECO-LARM.
SECO-LARM
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
Website: www.seco-larm.com
E-mail: sales
@
seco-larm.com
WARRANTY: ENFORCER Electromagnetic Locks are warranted against defects in
material and workmanship while used in normal service for a period of one (1) year from the
date of sale to the original customer. Our obligation is limited to the repair or replacement of
any defective part if the unit is returned, transportation pre-paid, to SECO-LARM.