SECO-LARM USA E-941DA-1K2P Door User Manual


 
ELECTROMAGNETIC LOCK Installation ManualELECTROMAGNETIC LOCK Installation Manual
SECO-LARMSECO-LARM
SECO-LARMSECO-LARM
SECO-LARM
®
U.S.A., Inc. U.S.A., Inc.
U.S.A., Inc. U.S.A., Inc.
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
Page 1
Website: www.seco-larm.com
E-mail: sales
@
seco-larm.com
WARRANTY:
ENFORCER Electromagnetic Locks are warranted against defects in
material and workmanship while used in normal service for a period of one (1) year from the
date of sale to the original customer. Our obligation is limited to the repair or replacement of any
defective part if the unit is returned, transportation pre-paid, to SECO-LARM.
PITGW1
E941SA1K2PD.pmd
ENFORCER
®
Also available:
HOW IT WORKS
When power is applied to the magnetic lock, it turns on the unit's powerful built-in electromagnet. This electromagnet is
attracted to the steel armature plate which is mounted on a door, holding the door fast against unauthorized entry. When
power to the magnetic lock is turned off, the electromagnet releases the armature plate, allowing the door to open. In
addition, the E-941SA-1K2PD has built-in LEDs to show electromagnet status, plus a status sensor to monitor whether the
door is securely closed, and a built-in adjustable-delay locking timer.
Installation Manual
E-941SA-1K2PD
1200 Pound Holding Force Electromagnetic
Lock with status sensor, LED status display
and adjustable time delay.
SPECIFICATIONS
Power
Magnet Size
Armature Size
Holding Force
Status Sensor
Status LED (2-Color)
Timer Delay
Current Drain
Voltage Tolerance
Housing
Temperature
Weight
E-941SA-1K2PD
12VDC/24VDC
10½ x 1
5
/
8
x 2
5
/
8
in. (268 x 42 x 67 mm)
7
1
/
4
x
5
/
8
x 2
3
/
8
in. (185 x 16 x 61 mm)
1200 lb. (545kg)
Relay, 3A @ 12VDC
Locked - Green, Unlocked - Red
1~78 seconds
500mA @ 12VDC, 250mA @ 24VDC
± 10%
Aluminum
14° ~ 131°F (-10° ~ 55°C)
11 lbs. (5.0 kg)
E-941DA-1K2P
-
Double-door 1200 lb. maglock with status
sensor and LED
E-941SA-1200
-
1200 lb. maglock without status sensor
E-941SA-600
-
600 lb. maglock without status sensor
E-941SA-300
-
300 lb. maglock without status sensor
NOTICE
The information and specifications printed in this manual are current at the time of publication.
However, the SECO-LARM policy is one of continual development and improvement. For this
reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is
also not responsible for misprints or typographical errors.
Copyright © 2003 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be
reproduced or copied, in whole or in part, without the written permission of SECO-LARM.
REGULAR MAINTENANCE
Clean the contact surfaces of the electromagnet or armature plate with a soft cloth and non-abrasive, non-
corrosive cleaner.
Apply a light coat of a silicon lubricant to prevent rust. Wipe away the excess.
Check that the armature plate is securely attached to the door, yet can pivot slightly around the armature screw.
Check that the electromagnet is securely attached to the door frame.
TROUBLESHOOTING
Problem:
Door does not lock
Status LED is not
illuminated
Door locks, but can be
easily forced open
Delay in door
releasing
No relay output
Delay in door relocking
Possible cause:
No power
Poor contact between
electromagnet and armature
plate
Incorrect voltage setting
A secondary diode was
installed across the
electromagnet
No power
• Misalignment
Check timer
Solutions:
Check to make sure the wires are securely tightened to
the terminal block.
• Check that the power supply is connected and operating.
Make sure the lock switch is wired correctly.
Make sure the electromagnet and armature plate are
properly aligned.
Make sure the contact surfaces of the electromagnet and
armature plate are clean and free from rust.
Check the power leads with a meter, and make sure
12VDC or 24VDC is present.
• The electromagnet is fitted with a metal oxide varistor to
prevent interference, so do not install a secondary diode.
• Check that the power is connected and operating.
Make sure the lock is aligned properly.
Make sure the NO/NC/COM are wired properly.
Make sure timer is adjusted to desired delay time.
SECO-LARM U.S.A., Inc.Page 4