Sears 661.62463 Air Conditioner User Manual


 
iNSTALLATiON
FINAL ASSEMBLY AND ADJUSTMENT
PUT FLOAT VALVE IN COOLER
Put the float valve through the spout hole and
cabinet hole Tighten the ring nut Be sure the float
moves straight up and down. TURN THE FLOAT
UNTIL A NARROW SIDE IS UP. Snap the Sp(ash
Guard Cover into the Water Spout as shown The
Water Spout and Splash Guard Cover are provided
to prevent water from "spurting "and splashing out-
side the Water Reservoir,
COMPRESSION
NUT
CONNECT WATER LiNE
For outdoor Hook Up, use #62527 Copper Hook Up
Kit or #62528 Plastic Hook Up Kit Both kits contain
all necessary fittings to connect water to cooler For
indoor kit use copper tubing and #62522 self pierc-
ing saddle valve.
PUT IN OVERFLOW PIPE (Fig. 11)
1 Push the drain fitting through the washer and
water tray hole Tighten the ring nut. Screw the
overflow pipe into the drain fitting Repeat for
the second tray.
NOTE: INSTALL DRAIN FITTING
INVERTED tF COOLER IS MOUNTED ON A
PAD. CUT OFF THE OVERFLOW PIPETOP
FLUSH WITH THE HEXAGONAL RING.
Put in the float valve side tray first The cros-
sover tube and grommet MUST be on the float
valve side (Fig 12).
Push the crossover tube into the grommet° Use
soap or detergent as a lubricant DO NOT USE
OIL,,
4 Put the second water tray in place. Push the
crossover tube into the grommeL
ADJUST WATER LEVEL
5_ Turn on the water. Check the water level when
the valve shuts off, If the water' level isabove the
tray water leve) mark bend the float rod down If
the level is too low, bend the rod up,,
FLOAT
VALVE
NUT
PREpSuS!ON _ FERRULE
%
ADAPTER
OVERFLOW
PIPE
WATER LEVEL
MARK
DRAIN FITTING
WASHER
I NOTE: CHECK THE CROSSOVER PIPE
GROMMETS AND ALL CONNECTIONS
FOR LEAKS.
PUT LOUVERS ON COOLER
GROMMET
CROSSOVER
PiPE
FLOAT
VALVE
Seepage 11
8