Sanyo KS3082 Air Conditioner User Manual


 
11
7. LED CLEAN Mode
In LED CLEAN mode, a UV anti-bacterial unit (including a LED
CLEAN lamp and anti-bacterial filter) in the indoor unit is used during
DRY, COOL, or FAN operation to remove bacteria from air blown
from the air conditioner.
Press the LED CLEAN button while operation.
The mark appears in the display.
To cancel, press the LED CLEAN button again.
When the LED CLEAN button is pressed, the UV anti-bacterial unit
operates for one hour and cleans air blown from the air conditioner.
Pressing the MODE selector button cancels LED CLEAN mode.
Do not open the front panel while the LED CLEAN lamp on the
display is on.
Depending on the room brightness, light from the LED CLEAN
lamp may reflect inside the air conditioner and be visible. This is
not a malfunction.
8. UNOCCUPIED Mode
Unoccupied mode is used to prevent the room temperature from
increasing too much when no one is in the room, and operate
automatically to save energy.
Press the UNOCCUPIED button.
The mark appears in the display.
To release the unoccupied function, press the UNOCCUPIED button
again.
Unoccupied Indication
Even if Unoccupied Mode is ON, it will be disabled if the air
conditioner is in operation.
Unoccupied Function can be set and released through all
operational modes, regardless of whether the air conditioner is
operating or not.
If the Unoccupied Function is ON and the remote control unit is
used to turn the air conditioner OFF (including OFF TIMER), the air
conditioner will turn off, but depending on the room temperature,
Cooling Operation will automatically begin.
When the Unoccupied Function is in operation and the ON/OFF
operation button is pressed, operation will restart based on the
settings input before the air conditioner was turned off.
In Cooling Mode: ( )
Unoccupied Mode triggers Cooling Operation in response to the
room temperature, but when this happens, the remote control unit
will continue to display the Operation mode set by the user.
If the room temperature rapidly changes, the room temperature
may get over the upper or lower limit when the unoccupied function
is activated.
The remote control unit should be used in the location specified in
“REMOTE CONTROL UNIT INSTALLATION POSITION” on
page 8.
The air conditioner’s stop order (stated in (2) / above) is valid only
when the unoccupied function is operated.
NOTE
Unoccupied
Function
Unoccupied
Indication
Status
OFF no display The unoccupied function is not set.
ON
flashing
The unoccupied function is now
being set, and under Cooling
operation.
lighting
Although the unoccupied function is
set, not under Cooling operation.
NOTE
(1)
89
86
82
(2)
Room
Temperature (°F)
Cooling
starts
Time
Cooling
stops
(1) When the room temperature rises above 89°F, Cooling
Operation will begin.
(2) When the room temperature drops below 82°F, Cooling
Operation will stop.
The above actions will repeat so that the room temperature is
maintained at about 86°F.
NOTE
OI-150-11-EG
01_KS3682_EN.fm Page 11 Friday, February 12, 2010 12:26 PM