Sanyo 18KHS22 Heat Pump User Manual


 
SUBMITTAL SHEET
SUBMITTAL SHEETSUBMITTAL SHEET
SUBMITTAL SHEET
SYSTEM
INDOOR/OUTDOOR
18KHS22 KHS1822/CH1822
WALL MOUNTED HEAT PUMP
GENERAL DATA (AT 230V)
POWER V/PH/HZ 230-208/1/60
Circuit Ampacity, Min. (A) 30
Fuse size, Max. (A) 30
COMPRESSOR Rotary-Hermetic
No. used 1
R.L. Amps - L.R. Amps (A) 7.1 - 52.0
Crankcase Heater (W) 30
OUTDOOR FAN - TYPE Propeller
Dia. (in.) - No. used 15 3/4 - 1
Type Drive - No. speeds Direct - 2
No. Poles - RPM (High) 6 - 1,020
No. Motors - HP 1 - 1/12
CFM (High) 1,190
F.L. Amps. (A) 0.5
OUTDOOR COIL – TYPE Aluminum Fin & Copper Pipe
Fin Type - Pipe Type Slit Plate - Inner Riffled
Rows - F.P.I. 2 - 15.9
Face Area (sq.ft.) 5.34
Tube Size (in.) 3/8
INDOOR FAN - TYPE Cross - Flow
Dia. & Length (in.) - No. used 4 & 30-1
No. speeds 3 & Auto
No. Poles -RPM (High) 4-1,600
No. Motors - HP 1 - 1/75
CFM (HI/MED/LOW) 440/380/320
F.L. Amps (A) 0.4
INDOOR COIL – TYPE Aluminum Fin & Copper Pipe
Fin Type - Pipe type Slit Plate - Inner Riffled
Rows - F.P.I. 2 - 14.1
Face Area (sq. ft.) 2.08
Tube Size (in.) 3/8
Drain Connection Size (in.) 1 - 1/4
REFRIGERANT R22
Lbs. - R22 (O.D. Unit) 4.25
Control Capillary Tube
Connection Flare
Line Length, Max (ft.) 65
Lift difference, Max (ft.) 23
Line Size - in. O.D. Discharge 1/4
Line Size - in. O.D. Suction 5/8
DIMENSIONS (in.) H x W x D
Indoor Unit -Uncrated 14- 3/16 x 39 x 7-13/16
-Crated 18 x 42-17/32 x 10-23/32
Outdoor unit -Uncrated 24-13/16 x 32-11/16 x 12-13/32
-Crated 28- 3/32 x 39- 5/32 x 16- 9/32
WEIGHT INDOOR OUTDOOR
Net (lbs.) 29.8 134.5
Shipping (lbs.) 37.5 143.3
Shipping Volume (cu.ft.) 4.8 10.3
SS18KHS22-1
PERFORMANCE DATA @ ARI STANDARD CONDITIONS (230/208V)
COOLING
Total Capacity (BTU/H) 16,500/16,000
Sensible Capacity (BTU/H) 10,390/10,060
Latent Capacity (BTU/H) 6,110/5,940
SEER 10.0/10.0
Dehumidification(Pints/H) 5.3/5.2
Amps (A) 8.0/8.6
Power Inputs (W) 1,810/1,760
HEATING
Total Capacity (BTU/H) 18,000/17,600
HSPF 6.8/6.8
Amps (A) 8.0/8.6
Power Inputs (W) 1,810/1,760
Back-up Strip Heater (KW) 1.80/1.47
Outdoor Sound Rating (bels) 7.8
FEATURE
Controls Microprocessor
Remote Controller LCD Wireless type
Temperature Control IC Thermostat
Timer ON/OFF, 24 hours
Night Setback Built-In
Air Louve (Horizontal) Manual
(Vertical) Automatic
Power Failure Automatic Restart Built-In
Self Diagnosis Built-In
Heating/Cooling Automatic Changeover Built-In
OPTION
Refrigerant Line Set AP2507BH (20 ft)
AP2510BH (30 ft)
AP2515BH (50 ft)
Low Ambient Control N/A
Fresh Air Intake N/A
Central Remote ON-OFF Control Available
Airduct Extension N/A
Indoor Frame Extension PLB 182
Condensate Drain Pump Available
Non-Removable Remo-con Bracket Available
OPERATING RANGE
Cooling Indoor Air Outdoor Air
Intake Temp. Intake Temp.
Maximum 95 F DB/71 F WB 115 F DB
Minimum 67 F DB/57 F WB 67 F DB
Heating Maximum 80 F DB/67 F WB 75 F DB / 65 F WB
Minimum - F DB/ - F WB 17 F DB/ 15 F WB
CERTIFICATION
18KHS22
AIRCONDITIONING PRODUCTS