Samsung AW12F2DBB Air Conditioner User Manual


 
Contents
PREPARING
YOUR AIR CONDITIONER
Safety Precautions ......................................................................................... 2
Air Conditioning Unit - Main Parts and Control Panel .................................... 4
Getting Started ............................................................................................... 5
OPERATING YOUR AIR CONDITIONER
Cooling Your Room ........................................................................................ 6
Setting the Off timer ....................................................................................... 7
Cancelling the Off Timer ................................................................................. 7
Switching the Air Conditioner Off .................................................................... 7
Adjusting the Air Flow Direction Horizontally .................................................. 8
Adjusting the Air Flow Direction Vertically ...................................................... 8
Using the Ventilation Lever ............................................................................. 8
RECOMMENDATIONS FOR USE
Operating Recommendation ........................................................................... 9
Temperature and Humidity Ranges ................................................................ 9
Cleaning Your Air Conditioner ........................................................................ 10
Solving Common Problems ............................................................................ 12
Technical Specifications ................................................................................. 12
INSTALLATION ....................................................................................................... 13
CC
CC
AA
AA
UU
UU
TT
TT
II
II
OO
OO
NN
NN
The maximum permissible system impedance at the power junction box is 0.24 ohms.
Usually, the maximum permissible mains impedance will not be exceeded when the
branch to the power outlet is fed from a junction box with a rated current of 32A.
AW18✴✴
" The high inrush current of the starting compressor motor can have adverse effects to
the operation of other equipment under unfavorable mains conditions. This equipment
does not comply with the relevant technical standards for the limitation of voltage
fluctuations and flicker."
Before connecting this equipment to the power supply system, please report to your
supply authority and obtain the consent.
Do not connect other electric appliances to the same supply lines.