Robertshaw 9801I2 Thermostat User Manual


 
CHOOSE HEATING/COOLING
To choose a mode (of operation), select Mode.
There are five possible operating modes:
Off – The heating/cooling systems are turned off, and will not operate.
Heat – The heating system is activated. The main screen displays the heat icon ( ).
Cool – The cooling system is activated. The main screen displays the cool icon ( ).
Auto Changeover – Either heating or cooling will be activated to maintain the temperature
setpoint. The main screen displays the letter A next to the or .
NOTE: Auto Changeover will be displayed only if activated in System Settings.
Emer – Emergency heat is activated. (This choice is available only when 1st stage Heat is set
as Heat Pump.)
The main screen displays a small letter E next to the .
Note: Emer will not automatically energize on the 9801i2. You will need to manually select it from the Current Mode menu.
Note: Balance points are not an option when an outdoor sensor is installed with the 9801i2.
When should I select Emergency Heat?
If your heat pump is not adequately providing heat, you can bypass it by selecting Emergency (heat) until the heat pump can be
serviced. In some installations, your thermostat may indicate a problem with the heat pump by displaying a message (on the main
screen) underneath the temperature. You may also want to select Emergency (heat) when the outdoor temperature drops below
freezing since the heat pump is very inefficient at low temperatures.
See Balance Points (page 22) for other options.