Robertshaw 9801I2 Thermostat User Manual


 
COMFORT SETTINGS page 2 of 2
Deadband is used only when the thermostat is set in the Auto Changeover mode. The deadband refers
to a band or range between the heating and cooling setpoints that controls how often the thermostat
switches from heating to cooling and vice versa.
The lower the deadband, the more often the thermostat will switch between heating and cooling,
usually in the fall and spring.
(For more information, see What is deadband? in FREQUENTLY ASKED QUESTIONS on page 29.)
The Warning shown to the left appears alerting you that Deadband adjustments may affect
Schedule data.
This means setpoints already entered into the program may be changed when the deadband
is put into effect.
When (Energy) Efficient Recovery is turned on (Yes), the thermostat attempts to reach the next
setpoint at the exact time of the next event. If you have two stages, the thermostat will use only the
first stage during this period. This is more efficient than waiting until the next event and then turning
on both first and second stages.
(For more information, see What is Energy Efficient Recovery™ (EER™)? in FREQUENTLY ASKED
QUESTIONS on page 29.)
18
Comfort Settings Menu
Back
Select
Sensor Program
Deadband 3.0°F
Efficient Recovery No
-----------
Warning!
Adjusting Deadband
May Adjust
Schedule Data.
Continue?
No
Yes
Comfort Settings Menu
Back
Select
Sensor Program
Deadband 3.0°F
Efficient Recovery Yes
-----------
110-1175 English 7/17/06 1:59 PM Page 18