Rinnai Q175C Boiler User Manual


 
Q175C Condensing Boiler
Q175C SP 2/2011
© 2011 Rinnai Corporation
SPECIFICATIONS
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior
notice. Local, state, provincial and federal codes must be adhered to prior to installation.
Standard Features
Onboard outdoor reset control system with sensor standard
Prebuilt plumbing kit with insulated Low Loss Header
Priority DHW standard (3 way valve not included)
Domestic hot water plate warming
Built in DHW 6.6 gallon indirect tank
Modulating Ceramic premix burner
5:1 turn down ratio
Spark ignition
Exceeds SCAQMD 1146.2 Low NO
x
requirements
Stainless Steel Water tube condensing heat exchanger
Direct Vent sealed combustion
Concentric and twin pipe venting adapters included
Approved for room and closet installations
Optional Accessories
RS100 Single zone controller
Flue Gas temperature sensor
Room Air Filter
NG to LP conversion Kit
LP to NG Conversion Kit
General Specifications
Units
Water content gal 1.8
Max. supply boiler
temperature
°F 176
Max operating pressure psi 45
Relief valve rating MBH 375
Relief valve pressure rating psi 30
Dry weight lbs 196
Min inlet gas pressure NG "W.C. 4.0"
Max inlet gas pressure NG "W.C. 10.5"
Min inlet gas pressure LP "W.C. 8.0"
Max inlet gas pressure LP "W.C. 14.0”
Max equivalent exhaust vent
length
ft 80
Max equivalent combustion
air vent length
ft 80
Approved venting materials
Polypropylene,
Stainless Steel,
PVC, CPVC
Performance Specifications
Units
Fuel Type NG/LP
Input MBH 175
Heating Capacity MBH 161
AFUE (I=B=R) % 95.7
Part Load Efficiency (EN677) % 98.5
DHW flow rate 75ºF ΔT
Gpm 4.1
Electrical Specifications
Units
Electrical Voltage Mains V/Hz 120/60
Electrical Voltage Controls V 24
Power Consumption Max Load W 210
Power Consumption Stand by Load W 14
Recommended Circuit breaker rating A 15