Rheem 22DV50-38 Water Heater User Manual


 
VENTING – ROUGHING IN DIMENSIONS (INCHES)
MODEL 4'VENTING SIDEVENTING(G) REARVENTING(H) OPTIONAL HEIGHT(A)
T
YPE NUMBER AVAIL.
MIN. MAX. MIN. MAX.
W
ITHVENTKIT #SP20061
DESCRIPTION FEATURES DIMENSIONS ENERGY INFO.
GAS INPUT IN RECOVERYIN FIRSTHOUR HT.TO TANK HT.TO VENT HT.TO SHIP. ENERGY AVG.ANN.
GAL. THOUS.BTU/HR. G.P.H. 90° RISE DEL.G.P.H. VENT HT. DIAMETER GAS CONN. SIZE SIDET&P WT. FACTOR OPER.COSTS
C
AP. MODEL NUMBER
NAT. NAT. NAT.
A
BC DEF(LBS)
NAT. NAT.
50 22DV50-40N* 40 40.4 85 68 57 21-3/4 14-1/4 5 51-1/4 164 0.58 $235
50 22DV50-38 38 38.4 85 68-108† 57 21-3/4 14-1/4 6 51-1/4 164 0.58 $235
40 22DV40S-36N* 36 36.4 65 63-98† 48-1/4 21-3/4 14-1/4 6 43 152 0.59 $231
TALL
T
Y
P
E
SHORT
G
E
A
B
C
F
D
H
10"
3/4" N.P. T.
RELIEFVALVE
OPENING
2"
1/2"
24-3/4"
EXTERIOR
WALL
(H:
REAR VENTING
RANGEOF
ADJUSTMENT)
(G: SIDE VENTING
RANGEOF
ADJUSTMENT)
TALL 22DV50-40N N/A 8-1/8 18-1/8 3-1/8 13-1/8 N/A
TALL 22DV50-38
Horizontal
8-1/8 48 3-1/8 43 72-107†
SHORT 22DV40S-36N
& Vertical
8-1/8 48 3-1/8 43 63-98†
Residential water heaters
from Rheem
Rheem Water Heating • 101 Bell Road, Montgomery, AL 36117-4305
800-621-5622 • sales@rheem.com • www.rheem.com
Rheem Canada Ltd./Ltée • Water Heater Division
128 Barton Street West, Hamilton, Ontario L8N 3P3
Not all models are available in Canada.
Printed in U.S.A. 05/07 WP Form No. 107-1 Rev. 1
FURY DIRECT VENT GAS FROM RHEEM
Get 4 More Years!
U
pgradeable warranty
with ProtectionPlus
Available in 40 Gallon Short 50 Gallon Tall Gas Models
6-Year Limited Tank and Parts Warranty*
With ProtectionPlus
the 6-Year Limited Tank Warranty Becomes 10 Years!
Adjustable coaxial vent allows
installation flexibility because
the coaxial vent can swivel
360 degrees, uses outside air
for combustion and requires no
electrical power
Aluminum vent and cap base to prevent staining
of building exterior
Brass drain valve
Factory installed temperature and pressure
relief valve
R-Foam
®
insulation for superior heat retention
Exclusive Rheemglas
®
tank lining resists
corrosion and prolongs tank life
Heat saving flue baffle design
Gas control and combination thermostat
Anode rod equalizes aggressive water action
Durable plastic formula dip tube
Meets or exceeds National Appliance Energy
Conservation Act (NAECA) requirements
*
See Residential Warranty Information Brochure for complete
w
arranty information.
Energy Factor and Average Annual
Operating Costs based on D.O.E.
(Department of Energy)test procedures.
D.O.E.national average fuel rate natural
gas 91¢/therm;LP $1.23/gallon.
®
* For SCAQMD rule 1121 compliance.
† With vertical Vent Kit #SP20061.
• If side wall is combustible material,
1" clearance must be included in adjustment range.
NOTE: Maximum adjustment range for vent system is 10"
for 22DV50-40N; 40" for 22DV40S-36N and 22DV50-38.
Review installation manual before
installation.
HOT WATER
CONNECTION
COLD WATER
CONNECTION
UPPER INLET
BOX ASSEMBLY
In keeping with its policy of continuous progress and product improvement,
Rheem reserves the right to make changes without notice.