Regency L900-NG1 Indoor Fireplace User Manual


 
Model L900-NG1 L900-LP1
Fuel Type Natural Gas Propane
Minimum Supply Pressure 5” W.C.(1.25 kPa) 12” W.C. (3.00 kPa)
Manifold Pressure - High 3.5” W.C. (0.87 kPa) 10” W.C. (2.49 kPa)
Manifold Pressure - Low 1.6” W.C. (0.40 kPa) 6.4” W.C. (1.59 kPa)
Ori ce Size #30 DMS #49 DMS
Minimum Input
Altitude 0-4500 ft. (0-1372m)
28,000 BTU/h (8.20 kW) 31,000 BTU/h (9.08 kW)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
41,500 BTU/h (12.16 kW) 38,500 BTU/h (11.28 kW)
Vent Sizing 5” Inner / 8” Outer 5” Inner / 8” Outer
Unit Dimensions Description L900-1
A Firebox Width w/ Standoff 51-1/2” (1308mm)
B Rear Firebox Width 40-5/8” (1032mm)
C Firebox Height 41-3/8” (1051mm)
D Height w/ Standoff 50-3/8” (1270mm)
E Unit Depth 27” (686mm)
F Height to Vent 44-1/2” (1130mm)
G Fireplace Opening Height 32-1/16” (814mm)
H Fireplace Opening Width 33-5/8” (853mm)
I Height to Fireplace Opening 3” (76mm)
L900-1 Gas Fireplace
Approved Venting Systems
Flex Vent Systems: FPI AstroCap™ Flex Vent
Rigid Pipe Vent Systems: Simpson Direct Vent Pro®
Selkirk Direct-Temp™
Metal-Fab® Sure Seal
Regency Liberty L900 Gas Fireplace
Unit Dimensions:
Framing Dimensions:
Non-Combustible Requirements:
Framing Dimensions Description L900-1
J Framing Width 52” (1321mm)
K*** Framing Height*** 50-3/4” (1289mm)*** + Hearth
L Framing Depth 26-1/2” (673mm)
M Minimum Height to Combustibles 60” (1524mm)
N Corner Wall Length 63-15/16” (1624mm)
O Corner Facing Wall Width 90-7/16” (2286mm)
P Vent Centerline Height 53” (1346mm)
Q Non-combustible facing height 17-7/16” (443mm)
R Gas Connection Opening Height 2” (51mm)
S Gas Connection Height 11-1/4” (286mm)
T Gas Connection Inset 6” (152mm)
U Gas Connection Opening Width 5” (127mm)
***
Important: Framing height requires consideration of the hearth
depth. Dimension K = K + the thickness of installed hearth.
WARNING
Failure to maintain required clearances is a major cause of chimney related res.
Installation of this replace must comply with these clearances
Please note: Due to ongoing product development, product appearance and speci cations
are subject to change without notice.
This manual is intended to be a Sales Reference Guide only.
Do NOT use for actual framing and installation of any unit.
Some speci cations may change without notice.
You must use the actual manual for exact installation speci cations.