Regency HI300 Indoor Fireplace User Manual


 
Model HI300
Optimum Effi ciency 77%
Emissions (grams/hr) EPA Certifi ed 3.8 grams/hr
Maximum BTU* 75,000 BTU
Maximum Log Size 18”
Firebox Size 2.3 cu. ft.
Flue Size 6”
Burn Time (typical)* up to 8 hrs.
* Length of burn time and BTU Range depends on type of wood, climate conditions and
installation.
83June 2007 Hampton Product Specifi cations Book
Wood Inserts
Wood Inserts
11-1/8”
23-3/4”
23-1/4”
11-1/4”
7-7/8”
17-1/4”
31-1/4”
51-3/4”
13-1/8”
48-1/8"
48-7/8"
Minimum Fireplace Opening
Height 21-1/2” (546mm)
Width 25” (635mm)
Depth 17-1/2” (445mm)
Dimension Description I2400
A Adjacent Side Wall (to side) 11” (280mm)
B
Mantle (to top)** 20” (508mm)
Mantle Depth (not shown) Maximum 10” (254mm)
C Top Facing (to top) 12” (305mm)
D Side Facing (to side) 8” (205mm)
E Minimum Hearth Extension* 18” (455mm)
F Minumim Heath Thickness* 0.5” (13mm)
G Minimum Hearth Side Extension 8” (205mm)
Side and Top facing is a maximum of 1.5" thick.
Floor protection must be non-combustible, insulating material with an R value of
1.1 or greater.
* Hearth thickness of 0.5" with k value = 0.84", R value = 6 or greater.
** A non-combustible mantel may be installed at a lower height if the framing
is made of metal studs covered with a non-combustible board.
Thermal fl oor protection is not required if the unit is raised 3.5" minimum (measured
from the bottom of the stove). However, standard ember fl oor protection is required.
It will need to be a non-combustible material that covers 16" (406 mm) in the US and
18" (450 mm) in Canada to the front of the unit and 8" (200 mm) to the sides.
If the unit is not raised, thermal fl oor protection required is 18" (450 mm) in the
US and Canada.
All fl oor protection must be non-combustible (i.e., metals, brick, stone, mineral
fi ber boards, etc.) Any organic materials (i.e. plastics, wood paper products, etc.)
are combustible and must not be used. The fl oor protection specifi ed includes
some form of thermal designation such as R-value (thermal resistance) or k-factor
(thermal conductivity).
HI300 Medium Wood Insert
HI300 Wood Insert
Unit With Cast Faceplate
17-1/4”
9”
11-1/8”
11-3/8”
8-1/2"
30-7/8"
23-1/4”
23-3/4”
42-1/2”
41”
40”
21-1/2”
30”
7-3/4”
Unit With Oversize Cast Faceplate
21-1/2”
34-5/8”