Raypak Gas Heaters Electric Heater User Manual


 
B
C
INDOOR
DRAFTHOOD
31-13/16"
7-3/4"
GAS
CONNECTION
J
A
20-1/2"
(22-1/2" ASME)
26-1/2"
ELECTRICAL
CONNECTION
34"
STACKLESS
OUTDOOR TOP
28"
4-3/8"
(3-3/8" ASME)
8-7/8"
(6-5/8" ASME)
Designation for a Digital heater using propane gas is “EP”; a Digital heater using natural gas is “EN”.
Prefix “P” is for plastic (polymer) headers; “C” is for cast iron (ASME) headers.
Suffix “X” is for cupro-nickel tubing; “C” is for copper tubing
Example: P-R407A-EN-X = Plastic headers, 407 model size, digital, natural gas, cupro-nickel
For elevations above 5000 feet consult the factory.
Manufactured under Patent No. 3,623,458.
Technical Data
Digital Low NOx Gas Heaters
Heater
Model
BTUH
Input
(000)
(A)
Cabinet
Width
(B)
Flue
Diameter
(C)
Indoor
Drafthood
(J)
Minimum Gas
Conn.
Water
Conn.
Shipping Weights (lbs)
w/ Polymer
Headers
and Stackless
Top
w/ cast iron
Headers
and Stackless
Top
Indoor
Drafthood
R207A 199.5 20” 6” 55-5/8” 12” 3/4” 2” 174 193 12
R267A 266.0 23” 7” 56” 11-1/8” 3/4” 2” 197 216 15
R337A 332.5 26” 8” 57” 10-3/4” 3/4” 2” 219 238 17
R407A 399.0 29” 9” 58-1/2” 12-1/2” 3/4” 2” 237 256 20
Amp Draw
120 volt 240 volt
6 3
HEATER
CAN BE INSTALLED DIRECTLY
ON A COMBUSTIBLE
SURFACE!
Swimming Pool and Spa
Heating Products
The Pool and Spa Heating Experts
sm