Pioneer MUH-GA20VB Air Conditioner User Manual


 
31
OPERATING PROCEDURE PHOTOS
4. Removing the compressor
(1) Remove the cabinet. (Refer to 1.)
(2) Remove the relay panel.
(3) Remove the soundproof felt.
(4) Remove the terminal cover on the compressor.
(5) Disconnect lead wires from the glass terminal of the com-
pressor.
(6) Recover gas from the refrigerant circuit.
NOTE : Recover gas from the pipes until the pressure gauge
shows 0 kg/cm
2
(0 MPa).
(7) Disconnect the welded part of the discharge pipe.
(8) Disconnect the welded part of the suction pipe.
(9) Remove nuts fixing the compressor.
(
10
)
Remove the compressor.
Photo 6
Compressor
Suction
pipe
4-Way valve
Discharge pipe
Compressor nuts
Glass
terminal
OB387-2.qxp 05.2.21 10:03 AM Page 31