Specication data luminaires
Philips indoor luminaires Technical data 12.5
Technical data
Protection against mechanical shock
Theimpactresistanceofaluminairedenestheprotectionofthe
luminaire against mechanical shock. The European standard EN 50102
denesthedegreesofprotectionagainstexternalmechanicalimpact
(IK code) and the method of testing. The luminaire housing should
withstandthedenedenergyofthemechanicalshockwithoutlosing
its electrical and mechanical safety, or the basic luminaire function.
Translated into a more practical implementation, this means that
after withstanding the shock, deformation of the mirror and housing
is allowed, although broken lamps, an unsafe electrical situation and
failuretomeetthespeciedIPclassicationsarenotpermitted.
The impact resistance is expressed as a group numeral, for instance
IK06, which is related to the impact energy.
All types of Philips luminaires have a minimum impact resistance of
0.2J.ThetableshowsthetenIKclassicationsandthedenedshock
energy expressed in joules. Notice that fully vandal-proof luminaires
are not available; vandal-protected (IK09) and vandal-resistant (IK10)
arethebestachievableclassications.
Protection against mechanical shock
IK code Shock energy (joules) Description Example
IK00 -
IK01 0.15
IK02 0.2 Standard Standard open luminaire, closed luminaire with acrylic cover
IK03 0.3
IK04 0.5 Standard plus Open luminaire with reinforced optical system
IK05 0.7
IK06 1
IK07 2 Reinforced
IK08 5 Vandal-protected Closedluminairewithpolycarbonateorhardenedglasscover
IK09 10
IK10 20 Vandal-resistant Closedluminaire
Ball impact resistance
For indoor sports halls ball-impact-resistant luminaires are essential.
As no European standards have been developed for this purpose,
PhilipshasclassiedtherelevantluminairesaccordingtotheGerman
DIN 18032. After the impact test according to this standard
(36 handballs targeted at a speed of 60 km/h) no damage of the
luminaire should have occurred and no loose particles should drop
down from the luminaire. The symbol for a ball-impact-resistant
luminaire is the football. Luminaires protected by a wire guard with a
grid width exceeding 60 mm are not to be used in tennis sports halls.
Flammability
Fromthepointofviewofammabilityofmountingmaterials,
luminairescanalwaysbemountedonnon-ammablebuildingmaterials
likeconcreteandstone.Ifluminairesaretobemountedonammable
materials special measures should be taken. Luminaires for discharge
lamps with no warning sign to indicate that they are unsuitable for
mountingonnormallyammablesurfaces,aresuitableformountingon
buildingsurfacesthatdonotignitebelow200°C.
Luminairemarkingforammability
Symbol Application Characteristicsofceilingmaterial
Suitable for direct mounting on
non-conbustible surfaces
Stone, concrete
Suitable for direct mounting on
normally flammable surfaces
Ignition temperature materials
>200°C;somecombustion
time lag
Suitable for direct mounting in/
on normally flammable surfaces
where thermally insulating
material may cover the luminaire
Ignition temperature materials
>200°C;somecombustion
time lag
Suitable for direct mounting on
easily flammable surfaces, where
combustible dust is present
Ignition temperature materials
<200°C;nocombustiontime
lag
Safety distance
Intheapplicationofreectorlampsandluminaireswithnarrowbeam
distributions of a high intensity, a minimum distance between light
source and illuminated surface has to be ensured. This is to prevent
too high temperatures of the illuminated surface. Minimum values for
safetydistancesarespeciedontheluminairepacking.Thespecied
values must be considered as the shortest distances permitted
between light source and illuminated object or surface to ensure
long-lasting safe operation.
Indoor_2008_Chapter_12_LIS.indb 5 20-05-2008 14:32:47