Philips H37 Indoor Furnishings User Manual


 
Section 5. Reactivity
Not applicable to an intact lamp.
Section 6. Health Hazards
Not applicable to an intact lamp. Breakage of the lamp may result in some exposure to the phosphor powder (for a
coated bulb) and to elemental mercury. No adverse effects are expected from occasional exposure to broken lamps, but
as a matter of good practice, prolonged exposure should be avoided through the use of adequate ventilation during the
disposal of large quantities of lamps.
WARNING! These lamps can cause serious skin burn and eye inflammation from short wave ultraviolet radiation if the
outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes
when envelope is broken unless adequate shielding or other safety precautions are used. Certain lamps that will
automatically extinguish when the outer envelope is broken are available commercially.
Emergency and First Aid Procedures: Apply normal first aid for glass cuts if such should occur through lamp breakage.
Section 7. Lamp Disposal Procedures
Normal precautions should be taken for the collection of glass particles in the event a lamp is broken.
Waste Disposal Method: All mercury vapor lamps contain some amount of mercury. When a mercury vapor lamp is to
be disposed, it is subject to the current EPA Toxicity Characteristic Leaching Procedure (TCLP) disposal criteria. This
test is used to determine if an item can be managed of as hazardous or non-hazardous waste.
Philips non-ALTO lamps (with black logo) are not TCLP compliant and should be managed as a hazardous waste under
the EPA Universal Waste Rules for fluorescent lamps. Mercury vapor lamps are not TCLP compliant.
All disposal options should be evaluated with respect to federal, state, and local requirements. Before disposing of waste
lamps, check with federal, state, and/or local officials for current guidelines and regulations. Philips encourages recycling
of its products through qualified recycling facilities.
Section 8. Control Measures
Respiratory Protection: None. NIOSH-approved respirator should be used if large quantities of lamps are being broken
for disposal.
Ventilation: Avoid inhalation of any airborne dust. Provide local exhaust when disposing of large quantities of lamps.
Hand and Eye Protection: Appropriate hand and eye protection should be worn when disposing of lamps and/or handling
broken glass.
Section 9. Regulatory Information
As a product, these mercury-containing lamps, when shipped in the manufacturer’s original packaging, may be regulated
for air, truck, or ocean shipment. As a waste, these lamps may be regulated in various states and local communities.
This safety data sheet does not constitute “knowledge of the waste” in certain jurisdictions.
This document supercedes previous documents: S05-93001 prepared 1991 and last revised 09/2005
and: S05-93002 prepared 1993 and last revised 06/2001
and: S05-93003 prepared 1994 and last revised 06/2001
and: S05-93004 prepared 1994 and last revised 06/2001
and; S05-93005 prepared 1993 and last revised 06/2001
and; S05-93006 prepared 1993 and last revised 06/2001
and; S05-93007 prepared 1993 and last revised 06/2001.
Occupational Health and Safety Administration (OSHA) Material Safety Data Sheet (MSDS) requirements for materials
are not applicable to manufactured articles in which individuals would not be subjected to materials contained in the article
during its normally intended use. The information in this document is provided as a courtesy and is intended to provide
relevant information in the event the articles it covers are encountered during unintended, or abnormal, circumstances.