Power Switches/ESB92
Common Specifi cations for Push Type Power Switches (Series R)
Type:
ESB92
Mechanical Specifi cations
Electrical Specifi cations and Operating Temperature
Terminal Strength
To withstand 10 N push force applied at the terminal top in any direction for
1 minute without damage or loosening
Lever Strength To withstand 50 N push force applied along the lever for 1 minute
Lever Wobble 1 mm max. in any direction at the lever top
Contact Pressure 300 mN min.
Contact Resistance After several non-loaded operations: 50 m
ȑ
max. (at 1 A 5 Vdc )
Insulation Resistance Terminal to Terminal, Terminal to Frame: 100 M
ȑ
min. at 500 Vdc
Dielectric Withstanding
Voltage
As per applicable Safety Standard
Operating Temperature –10 °C to +60 °C