Panasonic CW-C200KR Air Conditioner User Manual


 
9.1.1. Parts Identification.
9.1.1.1. Vertical Airflow Direction Vane.
Airflow direction adjustment Up-and-Down.
The vertical airflow direction vane is
controlled by positioning the vane to
discharge the air upwards, downwards
or straight out.
9.1.1.2. Ventilation Lever.
When the slide lever is in the:
“OPEN” position, the ventilation door
opens to allow air, smoke or odours to be
expelled from the room.
“CLOSE” position, the ventilation door is
closed and the air will be circulated inside
the room and conditioned.
9.1.1.3. Recommended.
Use the air conditioner under the following conditions:
Operating temperature range.
Indoor side Outdoor side
D.B.T. W.B.T. D.B.T. W.B.T.
Maximum
Temperature
32°C 23°C 43°C 26°C
Minimum
Temperature
21°C 15°C 21°C 15°C
D.B.T.: Dry Bulb Temperature
W.B.T.: Wet Bulb Temperature
Note: Humidity may exceed 90%.
Continuous operation at over 90% high humidity may
create condensation and result in water drops on the
intake and outlet vanes.
9 Operating Instructions
9.1. CW-C170KR, CW-C200KR, & CW-C240KR (Cooling only).
12
CW-C170KR / CW-C200KR / CW-C240KR / CW-A170KR / CW-A200KR / CW-A240KR