Changing the belt
If the power brush stops rotating it is
likely that the drive belt has snapped (usually
because the brush has been stalled). A spare
belt is supplied. Replacement belts can also
be obtained from Morphy Richards or a
Service Agent.
Removing the floor nozzle
cover
GH
1 Disconnect the cleaner from the mains
supply.
2 Place the cleaner upside down in the flat
position.
3 Use a cross-head screwdriver to remove
the two screws at the front and the
central screw under the height
adjustment mechanism G.
4 Turn the cleaner over and remove the
carpet height adjustment knob .
5 Remove the two screws at the rear and
lift the rear of the cover over the handle
release button and unclip the cover from
the front of the floor nozzle H.
Replacing the belt
IJ
6 If the belt has broken, ensure all pieces
are removed.
7 Lift off the belt cover Ï.
8 Grasp the brush bar Ì at both ends and
lift straight up.
9 Place one end of the new belt over the
metal motor shaft pin and the other
around the pulley end of the brush J.
10 Align brush end plates with their guide
slots and push the brush bar down into
place.
11 Re-fit the belt cover.
12 Re-fit the floor nozzle cover. Push the
carpet height adjustment knob back on.
13 Replace the two screws on the top of the
floor nozzle cover and the three screws
underneath the floor nozzle - do not
overtighten.