Monessen Hearth GLX28 Gas Heater User Manual


 
6
14D2099
PROPANE / LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w. c.
MANUAL / T-STAT PRESSURE MILLIVOLT PRESSURE
Regulator Pressure Setting: 10" w.c. Regulator Pressure Setting: 10" w.c.
Gas Inlet Pressure: Maximum 13" w.c. Gas Inlet Pressure: Maximum 13" w.c.
Minimum 11" w.c. Minimum 11" w.c.
NATURAL GAS
MANUAL / T-STAT PRESSURE MILLIVOLT PRESSURE
Regulator Pressure Setting: 3" w.c. Regulator Pressure Setting: 3.5" w.c.
Pilot Regulator: 3.5" w.c.
Gas Inlet Pressure: Maximum 10
1
/2" w. c. Gas Inlet Pressure: Max. 10
1
/2" w. c.
Minimum 5" w.c. Min. 5" w.c.
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
Manual control has four (4) positions:
OFF -All gas to the gas logs is shut off at the valve.
IGN -Valve position to light/maintain a standing pilot.
LOW -Minimum gas rate — front burner provides a realistic glow on the center log.
HI -Maximum gas rate — front burner provides a realistic glow on the center log, plus the rear burner
provides a pleasing yellow flame.
Gas Rate
Model Number Control Max BTU/Hr Min BTU/Hr
DLX18NV, GLX18NV Manual 26,000 16,000
DLX24/28NM, GLX24/28NM Manual 32,000 19,000
DLX18NT, GLX18NT T-Stat 26,000 16,000
DLX24/28NT Milli-Volt 26,000 20,000
DLX18NV, GLX18NV Milli-Volt 26,000 17,000
DLX24/28NV, GLX24/28NV Milli-Volt 32,000 22,000
Gas Rate
Model Number Control Max BTU/Hr Min BTU/Hr
DLX18PV, GLX18PV Manual 22,000 14,000
DLX24/28PM, GLX24/28PM Manual 33,000 19,000
DLX18PT, GLX18PT T-Stat 26,000 16,000
DLX24/28PT Milli-Volt 28,000 20,000
DLX18PV, GLX18PV Milli-Volt 22,000 17,000
DLX24/28PV, GLX24/28PV Milli-Volt 33,000 22,000
PRODUCT FEATURES AND SPECIFICATIONS