Monessen Hearth EYF18 Gas Heater User Manual


 
7
65D1009
EYF Series Unvented Gas Log Set

WARNING
         
       


Exception:


Use manufacturer's installation and clearance requirements
as defined in their manual.
The EYF Series unvented room heater is approved for
installation into the following unvented fireplaces:

The EYF Series unvented room heater may also be in-
stalled into a Ventless Firebox Enclosure for Gas Fired
Decorative Type Unvented Room Heaters per ANSI
Z1.91b.004, as long as firebox hearth dimensions meet
the minimum hearth dimensions shown below.
C
A
D
B
FP2530
hearth dims
Figure 2 -
Hearth Minimum Dimension for Solid Fuel Burning
Fireplaces and UL127 Factory Built Fireplaces
   
EYF18 5" 13" 17Z\x" 17"
(635 mm) (330 mm) (445 mm) (433 mm)
EYF4 w/ 9" 13" 19Z\x" 17"
EYF4-(R,F) (737 mm) (330 mm) (495 mm) (433 mm)
EYF4 w/ 33" 13" 5Z\v" 17"
EYF30-R (838 mm) (330 mm) (641 mm) (433 mm)
FP530

 

The following are guidelines for placing a gas log set in
a fireplace that has a restrictive barrier along the bottom
front opening of the fireplace. Some examples of barri-
ers are glass/screen door frames and sunken/recessed
fireplaces.
 
 
No Restriction 13”
1/” to 1Z\x 16”
Greater than 1Z\x” to 3” 16”
Greater than 3” *
*Any barrier greater than 3” placed in front of the gas log
set is not recommended by the manufacturer.
 Non combustible material such as refractory
brick may be used to line the floor of the fireplace in
order to raise the height of the gas log set in relation to
a restrictive barrier. If the unit is raised, the minimum
height dimension listed in the homeowner’s manual must
not be exceeded.
 If the log set is equipped with a remote receiver,
a restrictive barrier may reduce the battery life by
increasing the ambient temperature inside the fireplace.
Placement of the receiver outside of the fireplace will
extend the battery life.


   


WARNING
LO
HI
OFF
ON
I
G
N
X
FP2531
fireplace w barrier
Refer to
Table 1
Glass door frames
with adjustable
louvers should
have the louvers
fully open while the
unit is in operation
The log set should
be placed against or
as near as possible
to the rear wall of the
fireplace/firebox.
Height of restrictive barrier
caused by glass door frames,
recessed fireplaces, etc. from
the base or bottom surface of
the unit.
FP531
Figure 3 -
Reference Drawing of a Natural Flame Log
Set in an Enclosure