12 49D0090
49D0090 13
Never install the heater
• in a bedroom or a bathroom • in a
recreational vehicle • where curtains,
furniture, clothing, or other flammable
objects are less than 36 inches from
the front, top, or sides of the heater
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
WARNING
This heater creates warm air currents.
These currents move heat to wall
surfaces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater where
impurities (such as tobacco smoke,
aromatic candles, cleaning fluids,
oil or kerosene lamps, etc.) in the air
exist, may discolor walls.
CAUTION
IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms
without enough ventilation air may cause mildew to form from too much moisture. See Fresh Air for Combustion
and Ventilation, pages 8 through 10.
INSTALLATION
If you install the heater in a home
garage
• heater pilot and burner must be at
least 18 inches above floor.
• locate heater where moving vehicle
will not hit it.
CAUTION
For convenience and efciency, install heater
• where there is easy access for operation, inspection, and
service.
• in coldest part of room.
An optional fan kit is available from your dealer. See
“Accessories,” pages 28 and 29. If planning to use fan,
locate heater near an electrical outlet.
Continued
INSTALLATION OPTIONS
There are three options for mounting this heater.
A. Mounting heater to wall
B. Mounting heater to optional hearth base
C. Mounting heater to optional mantel (some mantels require the hearth base)