Mitsumi electronic MSGD10ND Air Conditioner User Manual


 
9
When the indoor unit is controlled with the remote controller, the operation mode, set temperature, and the fan speed
are memorized by the indoor electronic control P.C.board. The “AUTO RESTART FUNCTION” sets to work the moment
power has restored after power failure. Then, the unit will restart automatically. However if the unit is operated in “I FEEL
CONTROL” mode before power failure, the operation is not memorized. In “I FEEL CONTROL” mode, the operation is
decided by the initial room temperature.
How to release “AUTO RESTART FUNCTION”
1 Turn off the main power for the unit.
2 Pull out the indoor electronic control P.C. board and the power monitor, receiver
P.C. board. (Refer to 9-1.)
3 Solder the Jumper wire to the JR07 on the indoor electronic control P.C.board.
(Refer to 8-6.)
7-3. AUTO RESTART FUNCTION
NOTE:
The operation settings are memorized when 10 seconds have passed after the indoor unit was operated with the remote
controller.
If the main power is turned off or a power failure occurs while AUTO START/STOP timer is active, the timer setting is
cancelled.
If the unit has been off with the remote controller before power failure, the auto restart function does not work as the
power button of the remote controller is off.
To prevent breaker off due to the rush of starting current, systematize other home appliances not to turn on at the same
time.
When some air conditioners are connected to the same supply system, if they are operated before power failure, the
starting current of all the compressors may flow simultaneously at restart.
Therefore, the special counter-measures are required to prevent the main voltage-drop or the rush of the starting current
by adding to the system that allows the units to start one by one.
Operation
1 If the main power has been cut, the operation settings remain.
2 After the power is restored, the unit automatically resumes the same operation
as the memory has recorded.
However, it takes the compressor at least 3 minutes to get started.
JR07
IC101
CN151
SW1
CN112
CN111
CN201
52C/X10
C1
1
CN21
1
CN1V1
CN1R1
CN121