Maytag HRE2940L Water Heater User Manual


 
MODEL RATING PLATE
FLOOR DRAIN
DISCHARGE PIPE
(Do not cap or
plug)
6AIR GAP
HOT
18
COLD
TEMPERATURE-
PRESSURE
RELIEF VALVE
CONDUIT
HOT
COLD
Installation Checklist
1. Whether or not the element conversion is made, the model
rating plate must be marked. Using a hard point ink pen,
check the appropriate block within the model rating plate,
which is located adjacent to the lower access panel.
2. Is the fuse or circuit breaker size correct as shown in the
chart in the “Product Specifications” section?
3. Are the wires from the circuit breaker or fuse service to the
water heater’s junction box on the correct wire size (gauge) as
shown in the chart in the “Product Specifications” section?
4. Is the new temperature-pressure relief valve properly
installed, and piped to an adequate drain? See
“Temperature-Pressure Relief Valve” in the “Instructions
for Installation” section.
5. Is the water heater completely filled with water? See
“Filling the Water Heater” instructions in the “Instructions
for Installation” section.
6. Will a water leak damage anything? See “Locating the
New Water Heater” in the “Instructions for Installation”
section.
7. Are the cold and hot water lines connected to the water
heater correctly? See “Water Piping” instructions
in the
Instructions for Installation” section.
8. Is there adequate clearance for maintenance around the
water heater?
9. Do you need to call your electric company to check your
wiring?
Instructions for Installation (cont’d)