Maytag HN51240X Water Heater User Manual


 
Service and Maintenance
Venting System Inspection Burner Inspection
At least once a year a visual inspection should be made of the [ _WARNING
venting system.You should look for: _|Flood damage to a_may not be readily
Obstructions which could cause improper venting. The |visible or immediately detectible. However, over a
combustion and ventilation air flow must not be obstructed. "period of time a flooded water heater will create
dangerous conditions which can cause DEATH, SERI-
OUS BODILY INJURY OR PROPERTY DAMAGE.
Damage or deterioration which could causeimproper vent- Contact the Maytag dealer from whom the appli-
ing or leakage of combustion products, ance was purchased or call Maytag Customer Service
at 1-800-788-8899 for an authorized servicer to
replace a flooded water heater. Do not attempt to
Rusted flakes around top of water heater, repair the unit! It must be replaced!
At least once a year a visual inspection should be made of the
AWARNING main burner and pilot burner. The drawing is for your reference.
Chemical vapor corrosion of the flue and vent sys-
tem may occur if air for combustion contains certain You should check for sooting which is not normal and will
chemical vapors. Spray can propellants, cleaning sol-
vents, refrigerator and air conditioner refrigerants, impair proper combustion.
swimming pool chemicals, calcium and sodium chlo-
ride, waxes, bleach, and process chemicals are typi-
[ca compounds wh ch are potent a y corros ve.
Obstructed or deteriorated vent systems may pres-
ent a serious health risk or asphyxiation.
NATURAL GAS BURNER - 40 AND 50 GALLON
I ]
Be sure the vent _erly connected to I _)_
prevent escape of dangerous flue gasses which
could cause deadly asphyxiation.
AWARNING
If after inspection of the vent system you found PROPANE(L.R)GASBURNER-40AND50GALLON
sooting or deterioration, something is wrong. Call
the local gas utility or Maytag Customer Service at
1-800-788-8899 for an authorized servicer to correct
the problem and clean or replace the flue and vent-
ing before resuming operation of the water heater.
Failure to make corrections can result in a fire, or
explosion causing DEATH, SERIOUS BODILY INJURY,
OR PROPERTYDAMAGE.
NATURAL AND PROPANE (L.R) GAS BURNER - 75 GALLON
AWARNING
Soot build-up indicates a problem that requires cor-
rection before further use. Turn "OFF" gas to water
heater and leave "OFF" until repairs are made,
because failure to correct the cause of the sooting
can result in a fire or explosion causing DEATH,
SERIOUS BODILY INJURY,OR PROPERTYDAMAGE.
22