Lynx L-LS Indoor Furnishings User Manual


 
eDART System User Guide
Appendix 32
Lynx™ Mold-Closed Limit Switch
L-LS
The Lynx™ L-LS Mold-Closed Limit Switch is a tie-bar or
machine mountable machine cycle input module designed to be
used with the eDART System™.
The L-LS switch can be used to easily get a machine trigger off of
most injection molding machines by following the installation steps
below.
Figure 25: Lynx™ Mold-Closed Limit Switch side view
L-LS Installation
Step 1.
Switch the molding machine to Manual mode and close
the mold.
Step 2.
Set the limit switch on the tie-bar as shown in figures 26
and 27.
U
Always power down before working on
any equipment.
Be careful to note the position of the
ejector plate, the mold, the limit switch
and its cable, so the limit switch and/or
its cable does not get caught as the
mold opens and closes.
!
U