Lopi Clean Face Gas Fireplace Indoor Fireplace User Manual


 
Gas Input & Performance:
Adjustable High Heat System:
20,800 38,000 Btu's (NG)
23,500 38,000 Btu's (LP)
Heater Rated Fireplace: Heats up to 1,000 sq. ft.*
*Heating capacity will vary depending on the temperature zone
you live in.
Framing Dimensions:
See Installation Manual or visit www.lopistoves.com under Constitution
1. Hearth Requirements: Extends 10 from face and 4
9 1/2
2. wide when installed flush. Not required when raised 6
2.
(See Installation Manual or www.lopistoves.com for details)
2. Non-combustible facing - Two side and two top pieces provided
4. with fireplace.
3. Side Wall Clearance: 11
4. Mantle Clearances: 50 from base of fireplace.
4. Maximum allowed mantle depth: 12
5. Minimum fireplace enclosure height 60.
6. Measured from base of fireplace.
6. Minimum framing:
6. 50 wide x 56 3/4 tall x 25 deep.
7. Facing Requirements:
6. Provided fiber board or other non-combustible
6. material must extend from the base of the fireplace to
6 .the header and to the framing members on both sides
Features:
No grills for a traditional masonry fireplace look.
Durable, tempered glass with safety screen.
Screen is removable.
Fire viewing area 1080 sq. in.
Realistic, four-piece detailed log set with embers and twigs.
Digital Home Comfort Control System can be operated by
the hand-held remote control and the wireless wall control.
Operate Y
our Fireplace Green - The Electronic Gas Valve can
be run for greater efficiency in the Intermittent Pilot Mode
with the gas pilot turned off until you need it or St
anding
Pilot Mode,with the gas pilot always on, for reliable cold
weather operation.
Natural (NG) or Propane (LP) operation.
Uses Simpson Duravent 8 5/8 x 6 chimney
.
Seven Year Real World Warranty.
Tested and Certified by OMNI-Test Laboratories Inc. to ANSI Z21.88b
Vented Gas-Fired Direct Fireplace Heater.
Must be installed in accordance with all local codes, if any:if not, follow ANSI Z223.1
and the requirements listed in the Owners Manual.
Note: Improper installation of your gas appliance or failure to operate it in accordance to the guidelines detailed in the Owners Manual may
negate your warranty. We recommend all Lopi appliances be installed and maintained on an annual basis by your specialty hearth retailer.
4
1
1
2
6
5
1 to 1-1/2 Thick Cement Board
4
3
10 Min.
25 Min.
Maintain
a 14 min. width
between studs
and max. 3 1/2
depth of studs
for chimney
clearance.
41 1/2
7
Constitution
tm
Clean Face Gas Fireplace
Constitution
tm
Clean Face Gas Fireplace
We reserve the right to improve or change our products without prior notification. Consult the Owner’s Manual for complete installation requirements. Photos and illustrations are for descriptive purposes only.
Your Lopi Authorized Dealer is Located At:
Visit us online at: www.lopifire.com
© Copyright T. I. 10/2007 Printed in U.S.A.
#98800000