Linear VB-3 Home Security System User Manual


 
INSTR,INST,VB-2/VB-3
Linear P/N: 214074 B
Material: 20 Lb. Mead Bond
Size: 8.500 x 11.000"
Ink: PMS 561 (AQUA)
Scale: 1-1
VB-2 & VB-3
AUDIO MODULES
With 2-way Central Station
Audio (VB-2 only)
For Use With DVS-1200,
DVS-2400, DVS-2408,
Security Systems
Installation
Instructions
PRODUCT DESCRIPTION
The VB-2 and VB-3 Audio Modules are designed as add-on accessories for the
DVS-1200. DVS-2400, and DVS-2408 Security Systems. Each module plugs
directly into the unit’s circuit board. The modules provide voice prompts for
operating the system and voice feedback for remote command of the system
through a pushbutton telephone. The VB-2 module features 2-way audio and
audio listen-only capabilities for Central Station monitoring.
The digitally synthesized human voice produced by the module annunciates
important system information through the Console’s speaker or through a remote
speaker. Both modules are pre-programmed with a multi-word vocabulary. Each
time the system’s mode is changed, the voice module will sound the status of
the Console and its sensors. The volume control adjusts the voice level.
With either the VB-2 or VB-3 installed, and the Console connected to a telephone
line, local or off-site telephone sets can be used to control and interrogate the
DVS-2400 or DVS-2408. To gain access to the system, the user first enters their
user code. The module’s voice will then prompt the user to press various
telephone buttons to control the system. The DVS-1200 can be accessed only
from off-side telephones.
The VB-2 module supports 2-way audio communications with the Central Station.
The small microphone supplied fits into the Console’s case. The microphone’s
high-gain amplifier allows the Central Station to monitor the sounds in the
installation. The Central Station operator can control the direction of the 2-way
communications using a pushbutton telephone. In 2-way mode, the operator can
talk back to the subscriber through the Console’s speaker or a remote speaker.
1. COMPONENT LOCATIONS
2. CONNECT MICROPHONE 3. PLUG MODULE INTO CIRCUIT BOARD 4. MOUNT MICROPHONE
(760) 438-7000 • FAX (760) 438-7043
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
5. REMOTE SPEAKER & MICROPHONE 6. VOICE SYNTHESIS SETUP 7. REMOTE SYSTEM OPERATION
8. CENTRAL STATION AUDIO (VB-2 ONLY)
LINEAR LIMITED WARRANTY
This Linear product is warranted against defects in material and workmanship for twelve (12)
months. The Warranty Expiration Date is labeled on the product. This warranty extends
only to wholesale customers who buy direct from Linear or through Linear’s normal
distribution channels. Linear does not warrant this product to consumers. Consumers
should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There
are no obligations or liabilities on the part of Linear corporation for consequential
damages arising out of or in connection with use or performance of this product or
other indirect damages with respect to loss of property, revenue, or profit, or cost of
removal, installation, or reinstallation. All implied warranties, including implied warranties
for merchantability and implied warranties for fitness, are valid only until Warranty Expiration
Date as labeled on the product. This Linear Corporation Warranty is in lieu of all other
warranties express or implied.
All products returned for warranty service require a Return Product Authorization Number
(RPA#). Contact Linear Technical Service at 1-800-421-1587 for an RPA# and other
important details.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fill an important need in
portable wireless signalling. However, there are some limitations which must be observed.
For U.S. installations only: The radios are required to comply with FCC Rules and
Regulations as Part 15 devices. As such, they have limited transmitter power and
therefore limited range.
A receiver cannot respond to more than one transmitted signal at a time and may be
blocked by radio signals that occur on or near their operating frequencies, regardless of
code settings.
Changes or modifications to the device may void FCC compliance.
Infrequently used radio links should be tested regularly to protect against undetected
interference or fault.
A general knowledge of radio and its vagaries should be gained prior to acting as a
wholesale distributor or dealer, and these facts should be communicated to the ultimate
users.
Copyright © 1999 Linear Corporation 214074 B
2-WAY AUDIO
CONSOLE SPEAKER
VOLUME CONTROL
MICROPHONE
TERMINALS (VB-2 ONLY)
CONSOLE MICROPHONE (+)
MICROPHONE COMMON (-)
EXTERNAL MICROPHONE (+)
MODULE-TO-CONSOLE
CONNECTOR
MICROPHONE
(SUPPLIED WITH VB-2 ONLY)
DIGITAL VOICE
VOLUME CONTROL
MODULE-TO-CONSOLE
CONNECTOR
GAIN JUMPER
CUT JUMPER FOR USE WITH OLDER
DVS-2400/DVS-2408 OR IF
FEEDBACK OCCURS
MODEL VB-2
- ONLY -
CONNECT BLACK
MICROPHONE WIRE TO
CENTER TERMINAL
CONNECT RED MICROPHONE
WIRE TO THIS TERMINAL
SEE DVS-2408 INSTALLATION INSTRUCTIONS
FOR USE WITH THE DVS-2408
LINEAR SECURITY SYSTEM
MODEL DVS-2400/DVS-2408/DVS-1200
CIRCUIT BOARD
MODEL: VB-2 OR VB-3
VOICE MODULE
WARNING !
BE SURE ALL CONNECTOR
PINS ALIGN WITH CIRCUIT
BOARD SOCKETS
LOCATION OF VOICE
BOARD INSIDE CONSOLE
(ARROWS MUST POINT UP)
START BY INSERTING THIS
CONNECTOR PART WAY
COMPLETE INSTALLATION BY
ALIGNING PINS ON OTHER
CONNECTOR AND CAREFULLY
PRESSING THE MODULE IN
WARNING !
SMALL ARROWS ON
VOICE MODULE POINT UP
REMOVE POWER FROM CONSOLE
PRESS MICROPHONE
FIRMLY INTO MICROPHONE
MOUNTING HOLE
MODEL VB-2
- ONLY -
AC
AC
EXT. SPKR
(-)
H/A -
H/A +
RELAY N.O.
RELAY DRY
SYSTEM MAIN TERMINAL BLOCK
NOTE: REMOVE
JUMPER WHEN
USING AN
EXTERNAL
SPEAKER
REMOVE
JUMPER
VB-2 TERMINAL BLOCK
EXTERNAL MICROPHONE (+)
MICROPHONE COMMON (-)
CONSOLE MICROPHONE (+)
OPTIONAL REMOTE
SPEAKER & MICROPHONE
CONNECTIONS
LINEAR MODEL RSM-1
RSM-1 TERMINAL BLOCK
SPKR
SPKR
MIC (-)
MIC (+)
USE TWISTED PAIR
WIRE FOR MICROPHONE
RSM-1
TERMINALS
7
PRS
8
TUV
HOME
AWAY
1
1 FOR SPEAKER ENABLE
PROGRAMMING STEP #78
PROGRAM
STORE PROGRAM
START IN LEARN MODE
SWITCH THE SYSTEM
BETWEEN MODES TO
TEST THE AUDIO OUTPUT
SYSTEM ARMED
HOME MODE
ADJUST THE MODULE'S VOLUME
CONTROL TO SET THE VOICE LEVEL
PROGRAM THE CONSOLE
TO ENABLE AUDIO FROM
THE MODULE TO THE
SPEAKER
1
2
4
7
3
5
6
FROM A HOUSE PHONE
PRESS
ENTER A USER CODE THEN PRESS #
CONSOLE WILL REPORT MODE, ALARMS, AND TROUBLE
PRESS "1" TO SWITCH SYSTEM TO OFF MODE
PRESS "2" TO SWITCH SYSTEM TO CHIME MODE
PRESS "3" TO SWITCH SYSTEM TO HOME MODE
PRESS "4" TO SWITCH SYSTEM TO AWAY MODE
PRESS "5" TO LISTEN TO ALARM STATUS
PRESS "6" TO LISTEN TO TROUBLE STATUS
PRESS "7" TO LISTEN TO SENSOR STATUS
NOTE: THE SYSTEM
MUST BE CONNECTED
TO A TELEPHONE LINE
TO USE THESE
FUNCTIONS
DIAL THE INSTALLATION, LET IT RING
TWICE, HANG UP AND DIAL THE
INSTALLATION AGAIN (2ND CALL NEEDS
TO BE 10-30 SECONDS AFTER 1ST CALL)
THEN LISTEN FOR TONE
3
1
9
7
PRS
6
MNO
HOME
AWAY
0 FOR NO AUDIO MONITORING
1 FOR LISTEN-ONLY
2 FOR 2-WAY MANUAL
3 FOR 2-WAY FULL DUPLEX
PROGRAM
STORE PROGRAM
PROGRAMMING STEP #76
PROGRAM THE SYSTEM FOR
THE DESIRED AUDIO MODE
AFTER THE ALARM REPORT
IS SENT THE SYSTEM WILL
SWITCH TO THE PROGRAMMED
AUDIO MODE FOR 90 SECONDS
PRESS "9" TO DISCONNECT THE CALL
PRESS "3" TO LISTEN
PRESS "1" TO TALK
ALL
AUDIO
MODES
2-WAY MANUAL
AUDIO MODE
THE "1" AND "3" KEYS ARE NOT USED IN LISTEN-ONLY AUDIO MODE
MODEL VB-2
- ONLY -
THE "1" AND "3" KEYS CAN BE USED IN FULL DUPLEX MODE,
ALTHOUGH THE MODULE WILL SWITCH TO 2-WAY MANUAL
MODE UNTIL THE NEXT CALL