Lightolier VRA1G8LS132 Indoor Furnishings User Manual


 
VR PARABOLIC VRA1G8LS132
Page 1 of 2 1'x4' RECESSED FLUORESCENT, 3" DEEP, 8 CELL (1 ROW) PARABOLIC LOUVER
STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR NORMAL VDT USE
MOUNTING METHODS DIMENSIONS
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902 SECTION 2/Folio G05-36 REV. A
Features
Meets IES RP1 for lighting VDT areas with
normal use.
67.9% efficient (T8).
1.9 spacing mounting ratio.
Semi-specular low iridescence pre-anodized louver.
Vertical grain on louver eliminates reflected lamp image on cross
baffle.
Louver frame with integral positive light stop.
Spring loaded latches (self centering).
Reversible louver hinging.
Louver has protective dust guard.
Only 6-5/8" deep body.
Black housing exterior for cooler ballast operating temperature.
Turned-in edges for safe handling.
Built-in earthquake clip (pat. no. 5,072,344).
UL-Listed twin knockout access plate.
Air closure strips (optional).
Construction to meet NYC Code or Chicago Plenum is available.
G
exposed T-grid ceiling.
T
exposed slot T-grid ceiling.
F
plaster ceiling/flanged.
T
direct concealed two directional T-
grid ceiling.
earthquake clip
installed
6-1/2"
(165mm)
12"
(305mm)
12"
Accoustical
material
by others
1-1/2" max.
9/16"
Exposed slot
T-bar by others
Plaster
Opening
12-1/8"
12-11/16"
13/16"
Aluminum
flange trim
Plaster
by others
1-1/8" min
3-3/4" max.
Plaster frame
must be
ordered
separately
earthquake clip
before
installation
12"
3/8"
Accoustical
material
by others
1-7/8"
max.
1/4" max.
1/4" max.
Accoustical
material
by others
12"
15/16" or 1"
Exposed T-bar
by others
1-1/2" max.