Lightolier VPA2G27PP332 Indoor Furnishings User Manual


 
VP PARABOLIC VPA2G27PP332
Page 1 of 2 2'x4' RECESSED FLUORESCENT, 4" DEEP, 27 CELL (3x9) PARABOLIC LOUVER
STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR INTENSE VDT USE (PREFERRED)
MOUNTING METHODS DIMENSIONS
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902 SECTION 2/Folio G05-30 REV. A
Features
Meets IES RP1 for lighting VDT areas with intense use.
66% efficient (T8).
1.5 spacing mounting ratio.
Only 6" deep body.
One-piece housing.
Specular low iridescence pre-anodized louver.
Spring-loaded latches.
Concealed “T” hinges.
Louver frame with integral positive light stop.
Earthquake clips included.
Louver has protective film dust guard.
Air closure strips (optional).
Air flow pattern dampers (optional).
UL-Listed twin knockout access plate.
Construction to meet Chicago Plenum Code is available.
G
exposed T-grid ceiling.
T
exposed slot T-grid ceiling.
F
concealed Z-spline ceiling.
F
plaster ceiling/flanged.
T
direct concealed two directional
T-grid ceiling. (see options for
splay trim).
drywall kit (see options).
1/4" max.
1-1/2" max.
1-7/8" max.
24"
24"
9/16"
15/16"
or 1"
Type “G”
Fixture
Support
(by others)
24-5/16"
Ceiling
Opening
Drywall
(by others)
15/16"
1/4" max.
1-7/8" max.
24"
13/16"
24-11/16"
24-11/16"
1-1/8" min.
3-3/4" max.
1-1/8" min.
3-3/4" max.
6" (152mm)
Air supply slots
(VPA only)
3-1/2"
(89mm)
39-1/4" (997mm)
47-31/32" (1218mm)
24" (610mm)
6" (152mm)
2"x2-1/2" access plate