Lightolier E7059 Indoor Furnishings User Manual


 
Ceiling Cutout: 6 9/16" Dia.
Reflector Trims Frame-In Kit Lamp
E7059CLW Specular Clear finish with white flange E610 A19, 100W max.
E7059CLP Specular Clear finish with polished flange A21, 150W max.
E7059CL Specular Clear finish with molded trim ring (flangeless)
E7059 Add suffix for other finishes (see options)
5-7/8"
6" Dia.
6-1/2"
Flush
7-1/4"
Overlap
12
34
5
6
7
1-1/8" max.
Ceiling Thickness
3"
1" min.-
2-1/8" max.
(Ceiling Runner)
12-3/4"
4-1/2"
13-1/4"
10-1/4"
Molded
Trim Ring
Flush Trim
(Molded trim
ring removed)
Overlap Self-Flange
Matte White
or polished
Top View
Calculite
®
Incandescent Open Downlight E7059
Page 1 of 2 6" Aperture A19 / A21 Horizontal Lamp
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902
Features
1. Socket Cup: Heat dissipating die-formed aluminum contains medium base
porcelain socket with nickel plated screw shell wired with No 18 SF1 leads
to J-Box. Installs on reflector with positive position locking springs to assure
proper optical alignment of lamp to reflector — attached without tools. Can
be adjusted without tools to accommodate two different lamp sizes.
2. Mounting Brackets: Adjust vertically from inside of fixture. Durable 16 ga.
steel construction. Use with 3/4" or 1 3/4" lathing channels, or1/2" (11/16"
O.D.) EMT pipe (by others) or Lightolier accessory mounting bars.
3. Retaining Springs: Precision tooled springs secure reflector to mounting
frame for quick tool-less installation.
4. Reflector: 16 ga. Specular Alzak
®
aluminum, 50° visual cut-off to lamp and
lamp image. Available with white or polished flange, or with removable
white molded trim ring (field paintable).
5. Junction Box: 14 ga. steel, 4" x 3 1/2" x 2" box allows inspection from
below.
6. Thermal Protector: Meets NEC and UL requirements. Insulation must be
kept 3" away from fixture sides and wiring compartments and must not be
placed above fixture in a manner which will entrap heat.
7. Mounting Frame: Die-cast aluminum suitable for dry or plaster ceilings.
Provides flangeless trim in plaster ceiling.
Other Reflector Finish Options
Comfort Clear Diffuse CCD
Specular Gold GD
For additional finishes consult factory (GD not available with polished flange)
Flange Options
White W
Polished Flange P
Flangeless Leave Blank (molded trim ring)
Options & Accessories
18" Mounting Bars 1950 (set of 2)
27" Mounting Bars 1951 (set of 2)
T-Bar Anchor Clips 1956 (set of 4, for 1950 & 1951 bars)
Existing Ceiling Clips 7998 (set of 2)
Sloped Ceiling Adapters 7920 (see SCA specification sheet)
Step Down Transformer 7997 (see 7997 specification sheet)
Chicago Air Plenum LC (add suffix to Frame-in Kit)
Electrical
UL listed for maximum of 8 No. 12, 75°C through branch circuit supply conduc-
tors, or 60°C conductors for end of run.
Labels
UL Listed for damp locations, I.B.E.W.
Alzak
®