FIG. 4
INSTRUCTIONS FOR INSTALLING C12E28V SERIES DOWNLIGHT
REFLECTOR TRIM
1. Attach SOCKET CUP to REFLECTOR ASSEMBLY by aligning (3) SCREWS
with key slots in REFLECTOR NECK, then tighten screws. (Fig. 1)
2. Position REFLECTOR ASSEMBLY into MOUNTING RING of Frame-In
Kit or Cylinder, align (4) FLATS in REFLECTOR ASSEMBLY with (4)
CONE RETAINING SPRINGS, and align REFLECTOR SPRINGS with
UPPER SLOTS in MOUNTING RING (Fig. 1 & 2). Then raise REFLECTOR
ASSEMBLY, to snap in place. (FIG. 1)
3. Before lamping, make sure power is disconnected to fixture.
Install lamp into lampholder.
4. Install COVER GLASS (required for enclosed lamp rated
fixture), line-up the edge of COVER GLASS with one spring
opposite notch on REFLECTOR ASSEMBLY and gently
push glass outward, then lift glass upward into position.
Rotate COVER GLASS so that NOTCH in COVER GLASS
is away from NOTCH in REFLECTOR ASSEMBLY. (Fig. 1 & 3)
5: Hook SAFETY BEAD CHAIN onto BEAD CHAIN COUPLER.
Position CONE so that bead chain is about horizontal, then push
CONE up into MOUNTING RING, then turn CONE clockwise
slightly for tight fit onto ceiling. CONE RETAINING SPRINGS will
hold cone in place. (Fig. 1 & 4)
TO RELAMP
Disconnect power to fixture, then reverse installation
instructions above.
TO INSPECT AND REPLACE BALLAST
Disconnect power to fixture. Remove Cone. Detach REFLECTOR
A
SSEMBLY by disengage REFLECTOR SPRINGS, move it to side
of fixture in the plenum, or in cylinder, remove from cylinder. See
IS:C4-C12 (Frame-In Kit), and IS:C12CS (Cylinder), for ballast
replacement. After service reverse Installation steps.
Care and Maintenance of REFLECTOR TRIM finish
If handling of REFLECTOR TRIM with anodized finish is required, the use
of clean white or plastic film gloves is recommended to avoid fingerprints.
A
nodized surfaces can be cleaned by the following methods:
1. Wipe off with a soft, clean, dry, lint-free cloth.
2. Wipe off with a soft clean cloth dampened in mild detergent solution.
3. Rinse, then wipe dry with lint-free cloth or paper towel.
4. Wipe off with a clean cloth dampened with a solution of wetting agent
and water (such as 2 oz. Per gallon “Pluronic L62-LF” by Wyandotte
Products). Wipe dry.
5. Use a liquid wax such as Glass Wax®. Avoid gritty cleaning agents.
FIG. 1
FIG. 2 FIG. 3
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To
assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electric shock, turn off electricity at fuse box before proceeding.
Retain these
instructions for maintenance reference.
INSTRUCTION SHEET NO.
IS:C12
Page 1 of 2
A1204
INSTALLATION PROCEDURE FOR: 12” DIA. H.I.D. C12 SERIES REFLECTOR TRIM TO
C12 SERIES FRAME-IN KIT AND C12CS/C12CW CYLINDER (ORDER SEPARATELY)
IF A NON-IC TYPE RECESSED FRAME-IN KIT IS USED, DO NOT INSTALL INSULATION ABOVE NOR WITHIN
3 INCHES (76mm) OF ANY PART OF THE LUMINAIRE (LIGHTING FIXTURE)
WARNING: USE ONLY REFLECTOR TRIMS PROVIDED BY LIGHTOLIER. USE OF OTHER MANUFACTURES’ REFLECTOR
TRIMS MAY VOID THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD.