Lightolier Baselyte-BSL27 Indoor Furnishings User Manual


 
Lighting Systems Baselyte-BSL27
Page 1 of 8 3 Light T5 HO Indirect
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Ordering Information
Family
H = T5 HO
3 = Indirect
03
EN
H
3
BSL
03 = 3 Light
EN = Solid 04 = 4’
08 = 8’
12 = 12’
C = Custom Color
W = Standard
White
Distribution
Lamp Type
No. of Lamps
Housing
Module Length
Wiring
Voltage
Ballast Finish
Weight = 3.0 lb./ft
E = Standard
<10% THD
F = Standard
<10% THD
w/fusing
1 = 1cct.
2 = 2cct.
3 = 1cct. w/EC/NL
4 = 2cct. w/EC/NL
5 = 1cct. w/EM Battery
6 = 2cct. w/EM Battery
7 = 1cct. w/Dimming
8 = 1cct. w/1cct.
Thru wire
9 = 2cct. w/1cct.
Thru wire
Note: Please consult
wiring section of spec
sheets for more
wiring options.
Specifications
Features
1. Housing: die-formed 20ga. cold rolled steel
2. End Set: die-cast metal with baked powder coat finish
3. Lamping: three T5 HO lamps
4. Configuration: 4’, 8’ and 12’ module lengths or continuous rows
5. Ballasts: electronic 120V or 277V
Finish
High-quality white powder coat with textured matte finish.
Custom colors available. Consult factory.
Mounting
Aircraft cable gripper is tamper-resistant and provides infinite vertical
adjustment capability. Aircraft cable, crimp and cable gripper independently
tested to meet stringent safety requirements.
Electrical
All luminaires are factory pre-wired to module ends with quick-wire
connectors.
Joints & Intersections
Self-aligning joining system with hands-free pre-joining wire access.
Labels
UL, CSA standards.
Individual Fixtures
1. Determine the number of individual modules required
2. Order one end set per module
3. Order one non-power mount per module
4. Order one power mount per module
Continuous Rows*
1. Determine run length
2. Order the appropriate number and length of modules for complete run
3. Order one end set for each run
4. Order one non-power mount for each module
5. Order one power mount per run
6. Order one joiner per module minus one (e.g. 3 modules requires 2 joiners)
*Note: Some runs may require additional power mounts. Please see the
‘Run Configuration’ table on the next page for more details.
Ordering Instructions
D = Dual 120V
& 277V
1 = 120V
2 = 277V
Note: Option‘D’ is
standard. Voltage
options 1 and 2 are
only available with
EM Battery and
Dimming wiring
options.

