Lightolier AGW Indoor Furnishings User Manual


 
CANLYTE www.canlyte.com
525 EDUCATION ROAD, CORNWALL, ONTARIO, CANADA K6H 6C7 - (613) 938-6221
WE RESERVE THE RIGHT TO CHANGE DETAILS OF DESIGN, MATERIALS AND FINISH
© 2007 GENLYTE GROUP LLC (LIGHTOLIER DIVISION) AGR-AGW-1
Lighting Systems Agili-T Pendant Direct/Indirect AGR/AGW
Page 1 of 2 2 lamp T5 (lamp over lamp) 3 lamp T5 UP/DOWN per 4’ section
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Coplanar Solo Parabolic/Flat Blade Louver
LIGHTOLIER
A GENLYTE COMPANY
www.lightolier.com
TECHNICAL INFORMATION: (978) 657-7600 - (978) 658-0595
631 AIRPORT ROAD, FALL RIVER, MA 02720 - (508) 679-8131
Features
84.1% efficient (70% up/30% down) using T5 technology (2x F28T5).
Ultra-Light construction (4’ luminaire less than 15 lbs / 6.8 kg.) favors mobility, adds
installation and remodeling convenience.
Wide indirect distribution for uniform ceiling luminance.
Construction
Parabolic louver optic made of matte aluminum / Flat Blade optic incorporates a
white finish
Unique contoured louver design with integral light stop
Labels
Electrical
Standard product offering (DI version, 120V and 277V only) includes continuous 2-circuit
wiring, one circuit for the upper compartment (if applicable) and one circuit for the lower
compartment (if applicable). Single and double compartment luminaires can be mixed.
DA and DW available with Agili-T Network only.
18-gauge wire, maximum 10A per circuit.
Mounting
Suspension points on module: every 4’ (4’ luminaire)
Fast installation using mounting clip for Standard T-bar and Slim T-bar or for Slot T-bar
(see last page).
All canopy, suspension, power feed and mounting hardware included.
Finish
Seamless color and texture finish between luminaire and end-caps.
Available with textured (white or titanium) high resistant powder-based coating.
Options and accessories
• Emergency circuiting
** If electrical junction box is needed to connect emergency wiring, order AGEB, AGES
or AGEO.
*** 18-gauge wire. Maximum of 10A per breaker. 2 circuits using 2 breakers with common
neutral.
INDIVIDUAL CONTROL
• One circuit for AGR upper compartment controls 1 ballast and 2 T5/T5HO lamps
for indirect lighting ( per 4’ of luminaire).
• One circuit for AGR lower compartment controls 1 ballast and 1 T5/T5HO lamp
for direct lighting ( per 4’ of luminaire).
• Two ballasts allow control of direct/indirect light.
• Separate dimming available with Agili-T Network version.
54"
36"
3"
48"
7 3/16"
2 1/16"
2 7/8"
51-1/2” (1308mm)
48” (1219mm)
7-3/16”
183mm
2-7/8”
74mm
2-1/16”
52mm
36”
914mm
3”
76mm
Ordering information
AG
Family
AG: Agili-T
R
Type
R:
Direct /Indirect
Independant
Mount Coplanar
Solo with
Parabolic Louver
W: Direct /Indirect
Independant
Mount Coplanar
Solo with Flat
Blade Louver
4
Luminaire
Length
4: 4’
P
Mounting
P: Pendant
GR
Housing Finish
GR: Titanium
WH: White
DI
Wiring
DI: Direct Power
Feed
6 wires,4 wires
for 347V only
3
Lamp Qty
in a cross
section
2: 2 lamps
(lamp over
lamp)
3: 3 lamps
(2 up,
1 down)
28
Lamp
28: 28W T5
54: 54W
T5HO
UNV
Voltage
120: 120V
277: 277V
347: 347V
UNV:
Universal
Voltage
120/277V
PG
Ballast
DW: iGEN DALI
Adressable T5/T5HO with
Network-2
MultiSense
Integral Motion Sensor
(120 or 277V only)
DA: iGEN DALI
Adressable T5/T5HO
(UNV only)
PG: Electronic Program
Start T5/T5HO
Options