Lightolier ADS8G16MS140 Indoor Furnishings User Manual


 
VP PARABOLIC ADS8G16MS140
Page 1 of 2 8”x48” RECESSED FLUORESCENT16 CELL PARABOLIC LOUVER
STATIC IES RP24 PREFERRED
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
PERFORMANCE
In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1
reflectance 80% ceiling, 50% post-wall, 20% floor the CU. shall no be less than
0.69. To prevent glare the VCP shall not be less than 88 either lengthwise or
crosswise (at 100 fc level) and that the average luminance will conform with the
IES RP-24 preferred standard, and have a fixture efficiency of not less than 60%.
MATERIALS
Chassis parts are die-formed 20 gauge cold rolled steel.
LOUVER
Post-anodized aluminum.
FINISH
Louver - Low iridescense specular post-wall, anodized vertical grain sheet or
Low iridescence reflector matte post-anodized vertical grain sheet. Chassis exte-
rior white baked polyester powder coat.
ELECTRICAL
Rapid start HPF thermally protected class P ballast CBM certified by ETL if
K.O. is within 3 of ballast use wire suitable for at least 90.
LABELS
Listed by CSA/UL.
Meets IES RP-24 Preferred Practice.
Ideal for intensive VDT use areas.
Only 5.5 deep.
Utilizes CFI Advance Technology Reflector Louver.
Precise fitting reflector louver.
Louver securely held with CFI concealed torsionite spring clips
Fixture Efficiency 62.4%
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 (508) 679-8131 Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902 Section 2/Folio G09-10