Lightolier 8612E Indoor Furnishings User Manual


 
1 9/16"
10 9
7"
2"
5/16"
3 3/8"
2 3/4"
1
8
3
4
2
7
6
5
Lytespan
®
Accent Lighting System 8612E
Page 1 of 1 LyteJacks Remodeler PowerJack
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2006 Genlyte Group LLC • A0106
Features
1. Plug Housing: Aluminum die-casting provides support for the plug jack and
canopy.
2. Plug Jack: Molded high heat resistant polymer. Accepts all
LyteJack fixtures
3. Electronic Transformer
4. Transformer Housing: Aluminum sheet metal provides maximum
heat dissipation.
5. Thermal Protector
6. Thermoplastic Canopy: Snaps onto plug housing, covering the mounting
hardware. Exposed surface of canopy is treated to receive water base paint.
7. Mounting Plate: Galvanized steel supports the fixture on the
ceiling surface.
8. Locking Levers: Used to securely mount fixture to ceiling.
9. Housing Cover: Aluminum sheet metal may be removed to gain access to
transformer and wiring.
10. Housing Cover Screws: Remove screws to remove cover.
Electrical
60 Watt Class 2 low voltage (12V) Electronic transformer with auto-reset
thermal cut off. Supply circuit must be 120V-60Hz.
Dimming
Use only dimmers specifically designed for use with electronic transformers.
Low voltage fixtures may produce audible sound when dimmed.
Finish
All painted finishes baked enamel.
Labels
UL; CUL
8612E
Catalog No. Finishes Mounting Use With
8612EWH Matte White lnstalls in existing structurally sturdy ceiling 1/8" to 1 1/2" thick Lytedrops or Focal Jack
8612EBK Matte Black from below. 7 1/2" Minimum clearance is required above ceiling Luminaires 50W Max
8612EAL Aluminum thickness. Insulation must be kept 3" away from fixture sides and
wiring compartment must not be placed above the fixture so
as to entrap heat. Fixture is Non-IC Rated, Ceiling Mount only.