Lightolier 8091CB Indoor Furnishings User Manual


 
Lightolier is a Philips group brand
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • A0708
Calculite
®
CFL Open Downlight 8 0 9 1CB
Page 1 of 2 6" Aperture Triple Tube Cross Blade Louver
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Reflector Trim Frame-In Kit
8091CBW White Cone, White Flange
8091CBA Aluminum Cone, White Flange
S6132BU 6" aperture, 1 lamp 26/32W Triple Tube CFL (120/277V) 4-Pin (Amalgam)
Dimming Options:
S6132B
CU3 Lightolier PowerSpec 3% Dimming (120/277V) J1LD3 Lutron 3% Dimming (120V)
J2LD3 Lutron 3% Dimming (277V) JUM7 Mark 7 Dimming (120/277V)
J1MX Mark 10 Dimming (120V) J2MX Mark 10 Dimming (277V)
Other dimming product available, please consult factory
Remodeler Frame-In Kits
6126BURM 6" aperture, 1 lamp 26W Triple Tube CFL (120/277V) 4-Pin (Amalgam)
6132BURM 6" aperture, 1 lamp 26/32W Triple Tube CFL (120/277V) 4-Pin (Amalgam)
Features
1. Reflector: 16 ga. Die-formed aluminum, Anobrite
®
finish.
2. Socket Cup: Effectively dissipates heat and positions lamp holder.
Snaps onto reflector neck to assure consistently correct optical alignment
without tools.
3. Mounting Frame: Galvanized steel for dry or plaster ceilings. Accepts other
6” Triple Tube reflectors (see S6132BU Spec Sheet).
4. Retaining Springs: Precision-tooled steel friction springs secure reflector to
mounting frame for quick, tool-less installation.
5. Mounting Brackets: 16 ga. steel. Adjust from inside of fixture. Use 3/4" or
1 1/2" lathing channel, 1/2" EMT, or optional mounting bars.
6. Ballast/J-Box: Electronic 120V-277V. UL listed for through branch circuit
wiring with max of (8) No. 12AWG, 90°c supply conductors. Outboard-
mounted to reduce heat transfer and maintain lamp efficacy and life.
Service from below without tools.
7. Cross Blade Louver: Die-formed, 16 ga. aluminum, matte white or painted
aluminum finish. Accepts lens (consult factory). 50° cutoff to lamp, medium
beam. Keyed for orientation.
Electrical
Note: For ballast electrical data and latest lamp/ballast compatibility refer to
“Ballast” specification sheet for complete electrical data.
UL Listed for through branch circuit wiring with max of (8) No 12 AWG, 90
degree C supply conductors.
Options and Accessories
Other Louver Finishes Consult Factory
Emergency Add suffix EM*
Chicago Plenum Use 6132BULC
Existing/Thk. Ceiling FA EC6*
Emergency Ltg. Kit FA EM3E*
Fuse (Slow Blow) Add Suffix F
*See Spec. Sheets: FAEC, FAEM
Mounting Bars & Accessories; see Specification Sheet MBA.
Sloped Ceiling Adapters; see Specification Sheet SCA.
IC Frame available; see C6CFL32 specification sheet.
Labels
UL listed for damp locations.
7
2
345
6
6"
(152 mm)
5-7/8"" (149 mm) Dia.
7-1/4" Self-Flanged
Trim (184 mm)
1" (25 mm) min.-
2-1/8" (54 mm) max.
1-1/8" (29 mm) max.
Ceiling Thickness
3"
(76 mm)
1
Top View
13-7/8"
(353 mm)
11-1/8"
(283 mm)
10"
(254 mm)
4 5/8"
(117mm)
10"
(254mm)
12 3/4"