Lightolier 2000LVR Indoor Furnishings User Manual


 
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
LIGHTOLIER a GENLYTE company.
631 Airport Road, Fall River, MA 02720
®
INSTRUCTION SHEET NO.
IS:
2000LVR
B0698 Page 1 of 2
INSTALLATION PROCEDURE FOR REMODELER KITS 2000LVR
USE FOR 2000 SIZE TRIMS
1. CUT OPENING (Fig. A)
Use aperture sticker provided as a template to cut a hole in the
ceiling. Cut to outside edge of sticker.
2. WIRE-IN (Fig. B)
Wire to SUPPLY LEADS. (For CABLE, use built-in CABLE CLAMP
in J-BOX). WHITE FIXTURE LEAD to NEUTRAL SUPPLY LEAD.
BLACK FIXTURE LEAD to HOT (120V) SUPPLY LEAD. BARE FIXTURE
WIRE to SUPPLY GROUND. Use wirenuts (local hardware item).
Place all electrical connections in the J-BOX. Attach J-BOX cover
onto J-BOX. For flexible CONDUIT use 90° connector (not supplied)
(Fig. G) or 3/8” SPRING CONNECTOR (provided) (Fig. H). If 3/8”
SPRING CONNECTOR is used, place J-BOX and TRANSFORMER
ASSEMBLY onto ceiling, attach CONNECTOR to CONDUIT and
push into one of the 7/8” dia. knock out holes in J-BOX. Pull
J-BOX and TRANSFORMER ASSEMBLY toward ceiling opening
(as shown in Fig. B) and complete wiring.
3. PUT THRU AND ANCHOR (Fig. C)
1. Place J-BOX PLATE onto ceiling and push NAIL TAB into ceiling.
2. Push LONG LEGS of NAIL CLIPS (supplied in parts bag) into
RAISED BUMP of J-BOX PLATE and SHORT LEG into ceiling.
(Fig. I)
EXISTING CONSTRUCTION
Fig. A
1. Cut Opening
Fig. B
2. Wire-In
Fig. C
3. Anchor
Fig. D
4. Attach Mounting
Ring
Fig. E
5. Snap-On
Fig. F
6. Push-Up
WARNING: (RISK OF FIRE) DO NOT INSTALL INSULATION
WITHIN 3” OF FIXTURE SIDES OR WIRING COMPARTMENT,
NOR ABOVE FIXTURE IN SUCH A MANNER SO AS TO
ENTRAP HEAT.
3/8” 90°
CONNECTOR
Fig. G
Fig. H
Fig. I
3/8” FLEXIBLE
CONDUIT
TRANSFORMER
HOUSING
J-BOX
3/8” FLEXIBLE
CONDUIT
3/8” SPRING
CONNECTOR
J-BOX
J-BOX PLATE
RAISED BUMP
TRANSFORMER
HOUSING
NAIL CLIP
LONG LEG
NAIL CLIP
SHORT LEG
NAIL TAB