Lightolier 1104F18ESR Indoor Furnishings User Manual


 
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2006 Genlyte Group LLC • C1006
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lytecaster
®
Recessed Downlighting 1104F18ESR
Page 1 of 1 6 3/4" Aperture 0
®
1 Lt 18W Quad/Triple Tube Compact Fluorescent IC Remodeler
1
3
4
6 7/8"
3 5/8"
13 1/8"
DIAMETER
3 7/8"2 3/4"
5 1/2"
APERATURE
2
5
7 1/2"
OVERALL
HEIGHT
Complete Fixture consists of Reflector Trim & Frame-In Kit. Select each separately.
Frame-In Kit
Voltage Lamp
Reflector Trims — See Individual Reflector Trim Specification Sheets
Open Downlight
Enclosed
Diffusers
Wall
Washer
Cross
Blade
Anodized
Reflector Anodized
Cone Satin Cone Baffles Basic White
1104F18ESR 120V 18W
Quad or
Triple
Tube
1143
1144
1144CD
1112
1112NM
1113
1113BK
1113BKNM
1113CD
1113CDNM
1113NM
1113WH
1108
1108NM
1110
1110NM
1105
1105BNM
1105NM
1105WH
1176
1176WH
1179M1*
1179WH*
1170M1
1171
1121
1124
1126**
1128**
1134
1177SH
1177LX**
1178SH
1190**
1185
1186
1186WH
1135
1135WH
1132**
Ceiling Opening 7" diameter
Features
1. Housing: .032” (#20 ga.) UL listed for direct contact with thermal insulation.
Allows installation in ceilings up to 2" thick. Can be removed for access
to junction box, ballast and ceiling plenum. AirSeal
®
housing minimizes
air leakage to less than 2 CFM at 1.57 PSF (or 75pa), which complies with
Model Energy Code (Section 602.3.3) and Washington State Energy Code
(Section 502.4) and reduces heat loss and condensation in ceiling.
2. Junction Box: 2" X 4 1/2" X 3 1/2" (22 cu. in.) .032" (#22 ga.) galvanized
steel. UL listed for branch circuit wiring supplying connected luminaires.
Integral cable clamps permit attachment of non-metallic (#12 or #14 ga.)
Romex
®
cable without tools or additional connectors.
3. Socket Housing: Trim retaining spring secures trim to any height on
housing wall.
4. Socket: (4 Pin,GX24q-2) base, molded thermo-plastic. Pre-wired with #18
AWG leads to junction box.
5. Ballast: Electronic 120V, end of life protected, FCC class “B” consumer
limits, class “A” sound rating. Energy Star
®
qualified.
Electrical
Input Watts: 21
Amps: .33
Ballast Factor: 1.0 5
Power Factor: .50
Max THD %: <150
Min Start Temp: 0˚F/ -18˚C
* Recommend Triple Tube lamp for
optimal performance.
** Use Triple Tube lamp only.
Options & Accessories
AirSeal
®
Kit: LAS56R†
(Required for AirSeal
®
installation.)
Labels
UL (Type IC Suitable for Damp Locations)
†Complies with Air Leakage Requirements stated in the Model Energy Code,
California Title 24 and the Washington State Energy Code.
Romex
®
is a registered trademark of General Cable Industries Inc.
US and Foreign Patents Pending.