Lightolier 1050DRN Indoor Furnishings User Manual


 
Lensed Recessed CFL Downlighting 1050DRN
Page 1 of 1 5" Round, 1 Lt., CFL, Low-Profile IC Airseal
®
Energy Star
®
Dimming FIK
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • C1108
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier is a Philips group brand
1
2
2
3
5
6,7
4
8 1/4"
Overall Width
8 5/16"
13" Min
24" Max
Reflector Trim
Frame-In-Kit
14"
Overall Length
11 5/8"
Overall Length
Height = 3 1/2"
Aperture Opening = 5 5/16" Diameter
Top View
Complete Fixture consists of Frame-In Kit and Reflector Trim. Select each separately.
Xceed Frame-In Kit
Xceed Compact Fluorescent Lensed Round Reflector Trims
Lensed Downlight Lensed Slope/Wall Wash
1050DRN26ES*
(Energy Star
®
- 120v)
26w Triple
GX24q-3 Base
120v - 0.23 amp max
1050RNDLWB
1050RNDLCDW
1050RNDLCDP
1050RNDLWDW
1050RNDLWDP
1050RNSLWWB
1050RNSLWCDW
1050RNSLWCDP
1050RNSLWWDW
1050RNSLWWDP
* All frames come standard with preset mounting screws and a 2700K lamp. Models are available with preset nails and/or a 3500K
lamp. Simply add an N and/or 35 to the end of the model number for those options.
Features
1. Housing: .026" (#23ga.) galvanized steel. UL listed for direct contact with
thermal insulation. AirSeal
®
housing minimizes air leakage to less than 2
CFM at 1.57 PSF (or 75Pa), which complies with Title 24, the International
Energy Conservation Code, and Washington State Energy Code (Section
502.4). This reduces heat loss and condensation in ceiling. Access door for
inspection of junction box.
2. Lower Frame and Top Cover: .026” (#23 ga.) galvanized steel.
Accommodates ceilings up to 1 1/2" thick. 3/8" deep integral lip with four
notches at 90 degrees apart to simplify alignment. Locks into position along
length of mounting bars with locking screws. Indicator lines on housing top
and sides to simplify alignment.
3. Junction Box: 2.5" X 5 3/8" X 2" (27 cu. in) .032" (#21 ga.) galvanized steel.
UL listed 90°C supply conductors. Rated for branch circuit wiring supplying
connected luminaires (daisy chaining).
4. Mounting Bars: .059" (#16 ga.) galvanized steel. Bars pivot for easy
attachment and wire-in below ceiling line. Bars extend to accommodate 16"
to 24" O.C. joist spacing. Bars can accommodate 12" O.C. Joist spacing after a
slight field modification (see Instruction Sheet). Features integral self tapping
phillips/square drive SCREWS for secure attachment to wood or metal
construction. Also available with integral NAILS. Attaches to T-bar ceilings
without the need of accessories. Bars installed on shortest dimension of
frame, but can be easily repositioned 90 degrees from original position.
5. Ballast: Mounted inside Junction Box. 120V NPF Energy Star
®
approved
Electronic Ballast. Instant start with end of lamp life protection, class “P”
thermal protection with a class “A” sound rating. Ballast easily accessible
for inspection.
6. Socket: NEW TWIST & LOCK Four-pin base, molded thermoplastic socket,
prewired with No. 18 AWM leads to ballast.
7. Socket Bracket: .048" (#18ga.) Galvanized Steel. Designed to be easily
adjusted to accommodate 3/8" to 1 1/2" ceiling thickness. Three positions
available for any installation orientation of Wall Washers Slope ceiling, or
Wall mount application. Ensures Unitized optics. Reflector trim is secured to
upper portion of socket bracket to ensure a tight to ceiling installation.
Recommended Dimmers (Neutral Required)
ITSEBAU: IntelliSight Occupancy Dimmer for AmbiStar Ballasts
OS600EBA: Onset Wall Box Dimmer 600VA for AmbiStar Ballasts
MSP600EBA: MultiSet Pro Dimmer 600VA for AmbiStar Ballasts
Please add the following letters to part number for color option:
W = White I = Ivory LA = Light Almond
Recommended Lamping
Lightolier recommends the following Philips lamps:
943272: PLT 26W – 2700K = PHILIPS #38440-4
943273: PLT 26W – 3500K = PHILIPS #26824-3
Labels
cULus Listed (Type I.C., Suitable for Damp Location), Complies with Air Leakage
Requirements stated in the Title 24, the International Energy Conservation
code and Washington State Energy Code. AirSeal
®
is a registered trademark of
Lightolier.
T24
2005