Lightolier 1002 Indoor Furnishings User Manual


 
1. FRAME-IN (FIG. A)
Fasten MOUNTING FRAME to wood joist. Line-up bottom
edge of ADJUSTABLE MOUNTING BAR with bottom of
wood joist (Fig. E). Wire to supply leads. (For Cable, use
built-in Cable Clamp in J-Box.
NOTE: ADJUSTABLE MOUNTING can be extended for 24”
mounting. (For suspended ceiling, make certain that the
bottom of MOUNTING FRAME is no higher than 1” above
ceiling line Fig. F).
2. CLOSE-IN (FIG. B)
Install plasterboard or other dry type ceiling, as required.. Hole
in board can be cut either on the ground or after the board is
nailed to the ceiling. Use MOUNTING FRAME opening as cut-
ting guide. (Make sure ROTO CLIPS are rotated out of hole area
to cut.)
NOTE: For wet plaster ceiling, use Plaster Ring Accessory
(order separately).
No. 1960 for 1002 Frame-In Kit
No. 1961 for 1102 Frame-In Kit
No. 1962 for 1202 Frame-In Kit
3. SNAP-ON (FIG. C)
4. PUSH-UP (FIG. D)
®
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE.
This fixture is intended for installation in accordance with the National Electrical Code and local or Federal
code specifications. To assure full compliance with codes and regulations, check with your local electrical
inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
INSTRUCTION SHEET NO.
IS:1102
B0203 Page 1 of 2
Installation of Lytecaster
®
Frame-in-Kit 1002, 1102, 1202 (May be used with 7 • 11 or Lytecaster Reflector Trims)
WARNING – (RISK OF FIRE)
Do not install insulation within 3 inches of fixture sides or wiring
compartments, nor above fixture in such a manner as to entrap heat.
LIGHTOLIER a GENLYTE THOMAS company.
631 Airport Road, Fall River, MA 02720
See separate Instruction Sheet
for your choice of reflector trim.
U.S. PATENT NO. 4,039,822
OTHER U.S. AND FOREIGN PATENTS PENDING.