OPERATING INSTRUCTIONS LG 39E Multi User Combogard /Swingbolt
Keypad 3035, 3710, 3750 or 3750K with reading contact Lock 39E
Generally
Each pressing of a key is confirmed by a signal (an acoustic signal and a LED flash). A valid code is
followed by a double signal, an invalid code by a triple signal. After an interval of more than 10-seconds,
the already entered part of the code is deleted and the entire sequence has to be re-entered.
Code entering: Enter the seven-digit numeric code–or a word with 7 characters
a) Operation with parallel code: a double signal is followed.
(manager mode) Manager code: 1234567
b) Operation with dual codes: Six-digit numeric codes or words with six characters.
(must be programmed) For opening two valid codes must be entered.
Manager code: 123456 and User ID# 654321
Opening: Combogard: Enter the code and (after double signal) turn the
entry clockwise within 3 seconds unto the hold. The lock is open
and the entry is rotated.
Swingbolt: Enter the code and (after double signal) turn the
handle within 3 seconds into the OPEN position.
If the lock is not opened within 3 seconds, it is automatically
locked again.
Locking: Combogard: Turn the entry counter-clockwise unto the hold.
The lock is automatically closed and the entry stands straight.
(Check this by trying to turn the entry back again)
Swingbolt: Turn the handle into the CLOSE position.
The lock is automatically locked; check this by trying to turn the
handle into “OPEN” position.
I M P O R T A N T Check the lock to be locked.
Wrong try penalty: After four invalid codes, the entry is blocked for about 5
minutes. During this period, the lock signals at 10-second
intervals. After this time penalty, the entry of every second
invalid code initiates a new 5 minutes delay period.
The key pressing is refused with a triple signal.
Change of code: The user can change its code anytime.
(always with open door) Enter the code and keep pressed the last number until second
double signal (LED is on), press the “0” and enter the new code
(double signal), enter the new code once more for confirmation
(double signal).
The new code is now valid. If mistakes are made while
changing the code or if an interval occurs of more than 10
seconds, the old code remains valid and the entire sequence
has to be re-entered.
Test the new code several times by open door!
Contact of
the audit trail
LED
3035 3710
3750 3750K