LG Electronics ESG-2008-V1 Air Conditioner User Manual


 
PACKAGED TERMINAL AIR CONDITIONERS
PACKAGED TERMINAL
AIR CONDITIONERS
Ultra-quiet operation is the hallmark of LG’s new line of PTAC products. Low decibel levels and outstanding
sound prevention rating make this your best choice for a quiet environment. And with efficiency ratings up
to 12.5 EER, these units are also your energy efficient choice.
Other features include standard connections for remote thermostat and front desk controls. Gold Fin
technology protects the unit from the corrosive effects of outside air and extends the operating life of PTAC
models. And the industry standard size makes installation easy and economical.
7,000–15,000 BTUs
Floor Standing
Ceiling Cassette
Type
A/C
A/C
A/C
A/C
System #
LF300CP
LF480CP
LC240CP
LC340CP
Pipe size
Liquid Suction
3/8" 5/8"
3/8" 3/4"
1/4" 1/2"
1/4" 5/8"
BTUs
24,000
44,000
24,000
34,000
Additional
Refrigerant
0.32 oz./ft.
0.42 oz./ft.
0.32 oz./ft.
0.42 oz./ft.
Max.
Pipe Length
100'
131'
100'
115'
Max. -
Elevation
66'
82'
50'
66'
Refrigerant Line Specifications
Each system is pre-charged with enough refrigerant to charge 25 ft. of line and the interior unit.
NOTE: Systems having the outdoor unit mounted above the indoor unit (e.g. basement
installations) have the following additional requirement:
For systems with maximum elevation of 25 ft. (see chart above and Figure A), refrigerant lines
must be oil trapped between 8 ft. and 16.4 ft. of elevation.
For systems with elevation of greater than 25 ft. (see chart above), refrigerant lines must be oil
trapped at least every 16.4 ft. of elevation.
DUCT-FREE • FLOOR STANDING & CEILING CASSETTE • SINGLE ZONE
ELECTRICAL & REFRIGERATION QUICK REFERENCE
25' maximum
8' minimum
16.4' maximum
OIL TRAP
INDOOR UNIT
OUTDOOR UNIT
Figure A. Example: 25 ft. maximum
elevation.
Floor Standing
Ceiling Cassette
Type
A/C
A/C
A/C
A/C
System #
LF300CP
LF480CP
LC240CP
LC340CP
Indoor Outdoor
230/208 230/208
230/208 230/208
230/208 230/208
230/208 230/208
Voltage
BTUs
24,000
44,000
24,000
34,000
Rated
Amps
11.5/11.5
20.0/20.0
11.5/12.4
11.5/16.5
MCA*
20
30
20
30
MOP**
30
40
30
40
Electrical Specifications
Digital Control Panel
Manual Control Panel Wireless Digital
Thermostat
*Minimum Circuit Ampacity
**Maximum Overcurrent Protection
Wire Size
Minimum wiring requirements suggested by manufacturer.
Minimum AWG 14-3
Indoor/Outdoor Connecting Cable Minimum AWG 14-3
All equipment single phase.
33
34
NOTE: Please see local electrical codes for proper wire specifications.