LG Electronics 115V Dehumidifier User Manual


 
MODEL EVOLUTION LGR
F292
CONTROLS TOUCHPAD
TYPE LOW GRAIN REFRIGERANT HOUR METER YES
HEIGHT 33.5" (85 CM) WATER PUMP-OUT CENTRIFUGAL
WIDTH 20.7" (52.5 CM) DRAIN HOSE LENGTH 40 FT (12.2 M)
DEPTH 20.7" (52.5 CM) AIR FILTER 3M™ HIGH AIRFLOW*
USE WEIGHT 92 LB (42 KG) WHEELS SEMI-PNEUMATIC
WATER REMOVAL AHAM 70 PINTS/DAY (33 LTR) HANDLE COLLAPSIBLE METAL
80° F/20% RH 7 PINTS HOUSING ROTOMOLDED
OPERATING RANGE 33° - 90° F (1° - 32° C) POWER 115V 5.6 AMPS
COMPRESSOR TYPE 5,595 BTU ROTARY CORD LENGTH 25 FT (7.6 M)
DEFROST TYPE HOT-GAS BYPASS SAFETY MARKS UL
PROCESS AIR 160 CFM (272 CMH)
TROUBLESHOOTING
For any problems not listed below, call your local distributor or contact our Service Department toll free at 888-867-
3235.
Unit does not operate No power to machine
Switch not turned on
Plug in the unit; check power at outlet.
Turn on switch.
Compressor will not start Unit needs 5 minutes before restart
Overload preventing start up
Switch off unit, wait 5 minutes before starting.
Reduce room temperature below 90° F (32° C).
Blower wheel not turning Obstructed blower
Loose blower wheel set screw
Remove obstruction.
Tighten Screw.
Unit operating, but room not dry Not enough time to dry
Poor air movement in room
Excessive air infiltration
Allow more time for drying.
Increase airmovement with TurboDryers.
Reduce airflow into the area being dried.
Unit continuously in defrost Room temperature too low Increase room temperature.
Unit collects little water Room air is dry
Room temperature too low
Airflow through unit restricted
Check humidity with hygrometer.
Inrease the room temperature.
check filter and coils, clean if debris.
Pump does not function Stuck float valve Clean float valve shaft.
PROBLEM
CAUSE
SSSOLUTION
SPECIFICATIONS
07-01480C LW 04-13 Copyright 2007 Dri-Eaz Products, Inc.
7