Other displays
Defrost Cycle
During normal operation, the temperature sensor detects frost forming on the
coils, causing a defrost cycle to start. The display will read DEFROST ON.
Dehumidification stops during the defrost cylce. When the unit completes the
cycle the display will return to DEHUMIFIER ON.
Messages
When the display menu shows the error message "GET SERVICE," followed
by "ER01" or another numeral, follow these steps:
1. Unplug the unit and then plug it back in. This may re-set the
electronics.
2. If that does not fix the problem, try the solution if one is listed in
the “Error Message Table” to the left.
3. If that does not fix the problem, contact the Dri-Eaz Service
Department at 888-867-3235.
Maintenance
MAINTENANCE INTERVALS
Before Each Use
• Inspect the electrical cord for damage. Look for fraying, cuts, etc. Do not
use the unit if you find any. Call Dri-Eaz for the nearest Service Center.
• Inspect filter. Look for accumulated dust and dirt that would restrict airflow
through the filter into the unit. If any is visible, vacuum out the debris. Do
not wash the filter, as it will reduce the effectiveness of the electrostatic
material.
IMPORTANT: Replace the filter whenever:
• It has been vacuumed clean 3 times
• It has been used on a mold remediation job
ER
1,2,3,5,
6
Problem with electronic
control panel. Contact Dri-
Eaz Service at 888-867-
3235.
ER 4
Check the temperature or
sensor cable, contact
Service for instructions
888-867-3235.
ER 8
Check the touchpad key.
Press and release each
key several times.
ER 9
Check for obstructions or
kinks in the drain hose.
WARNING
ELECTRIC SHOCK HAZARD
Unplug any DrizAir dehumidifier before performing maintenance.
WARNING
Electric Shock Hazard
Unplug unit before performing
any maintenace.
Never use a water hose or pres-
sure washer to clean coils; water
could enter the electrical cam-
partment causing a shock haz-
ard.
Follow cleaning instructions in
manual.
PURGE. Press the PURGE key to empty water from the pump
reservoir. During normal operation, the pump purges automatically
every six minutes, or whenever the reservoir is full. The display will
read PUMP PURGING with a numeral countdown.
To purge the pump manually:
1) Turn the power off using the OFF key, and let the unit sit
plugged in for about 10 minutes. This allows water to drip
from the coils.
2) Press PURGE to remove residual water.
READ AND SAVE THESE INSTRUCTIONS
Error Message Table
07-01480C LW 04-13 Copyright 2007 Dri-Eaz Products, Inc.
5