Lance Industries 6999 Vacuum Cleaner User Manual


 
{
How to Replace Worn Belt or Light Bulb
NOTE: Disconnect power cord and wands from electrical hose before replacing belt or bulb. Belt pulleys can become
hot during normal use. To prevent burns, avoid touching the belt pulley when servicing the drive belt.
3. Lift out brush roll; replace new belt around brush roll
shaft.
2. Remove two screws located in front of the light bulb
and lift up to remove the brush roll cover.
1. Remove two screws from bottom side. To turn over,
grasp hood near handle socket and lift forward.
Replace headlight bulb, if necessary. Support socket
with one hand and push light bulb into socket; turn to
release. Place new light bulb into socket; turn to secure.
Push light bulb and socket back so bulb will not touch
lens cover. Use GENUINE EUREKA replacement bulb,
59224.
Continue to step 2 to change belt. Skip to step 7
and 8 to replace hood on motorized nozzle.
4. Return brush
roll into base.
5. Rotate belt onto motor pulley.
6. Replace brush roll cover.
Use GENUINE EUREKA replacement belt, 52201C.
7. Tilt cover over ridge and push down.
8. Secure with screws on underside (refer to 1).
Brush
Roll
Pulley
Motor Shaft
{
9
Look for the symbol.
Open filter cover by lifting up on
latches and pulling filter cover out
and away from the cleaner.
Clean or replace washable HEPA
filter. Clean or replace final filter in
filter cover and close cover.
Ensure the filter cover is
securely fastened.
Use GENUINE EUREKA washable HEPA filter, 61053. To clean filter rinse dirty
side of filter under warm, low pressure water being careful not to get the clean side
wet (this increases drying time). Do not put damp filter back in vacuum cleaner.
Allow to thoroughly air dry.
Final Filter
(underneath
side)
Ridge
How To Change or Clean Washable HEPA Filter and Final Filter (Model 6999 only)
Use GENUINE EUREKA Final filter, 61262. The final filter can be cleaned. Run under water and allow to thoroughly air dry.